Difference between revisions of "ASM 10.4.4 Ridge (Snap Seam, Notched)"
Difference between revisions of "ASM 10.4.4 Ridge (Snap Seam, Notched)"
(→RELATED WORK BY OTHERS) |
|||
Line 1: | Line 1: | ||
− | |||
[[File:8.1.4.12.1.jpg]] | [[File:8.1.4.12.1.jpg]] | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
+ | ;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope. | ||
+ | ;(2) '''Insulation Overlay Protection''': Recommended. | ||
+ | ;(3) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMPANEL |'''Architectural Metal Roof Panel''']] : Turn up (bread panned) at termination. | ||
+ | ;(4) 'Z'-Bar: Installed to meet adequate attachment for UL I-90 wind uplift requirements. | ||
+ | ;(5) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMINS |'''Insulation''']]: Installed between ‘Z’ bars or wood battens on 600 mm (24") centres. | ||
+ | ;(6) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLOSURE |'''Pre-formed Foam Closures''']]: Set in accepted caulking. | ||
+ | ;(7) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMEXFASTEN |'''Exposed Fasteners''']]: High domed, gasketed cladding type screws compatible with metal roof panel. | ||
+ | ;(8) '''Metal Cap Flashing''': Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2"). | ||
+ | ;(9) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDRAG |'''Drag-load Fasteners''']]: Compatible non-corrosive fasteners. | ||
− | + | <hr> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
+ | ;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']] | ||
− | |||
− | |||
− | |||
− | |||
+ | '''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements. | ||
<hr> | <hr> | ||
Line 36: | Line 25: | ||
+ | [[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Application'']] | ||
− | + | [[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']] | |
− | |||
− | [[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa | ||
− | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']] |
Revision as of 18:19, 10 August 2016
1 WORK INCLUDED
- (1) Underlayment
- The type of underlay required is determined by roof slope.
- (2) Insulation Overlay Protection
- Recommended.
- (3) Architectural Metal Roof Panel
- Turn up (bread panned) at termination.
- (4) 'Z'-Bar
- Installed to meet adequate attachment for UL I-90 wind uplift requirements.
- (5) Insulation
- Installed between ‘Z’ bars or wood battens on 600 mm (24") centres.
- (6) Pre-formed Foam Closures
- Set in accepted caulking.
- (7) Exposed Fasteners
- High domed, gasketed cladding type screws compatible with metal roof panel.
- (8) Metal Cap Flashing
- Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2").
- (9) Drag-load Fasteners
- Compatible non-corrosive fasteners.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.