;(2) '''Insulation Overlay Protection''': Recommended. | ;(2) '''Insulation Overlay Protection''': Recommended. | ||
;(3) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMPANEL |'''Architectural Metal Roof Panel''']] : Turn up (bread panned) at termination. | ;(3) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMPANEL |'''Architectural Metal Roof Panel''']] : Turn up (bread panned) at termination. | ||
− | ;(4) 'Z'-Bar: Installed to meet adequate attachment for UL I-90 wind uplift requirements. | + | ;(4) ''''Z'-Bar''': Installed to meet adequate attachment for UL I-90 wind uplift requirements. |
;(5) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMINS |'''Insulation''']]: Installed between ‘Z’ bars or wood battens on 600 mm (24") centres. | ;(5) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMINS |'''Insulation''']]: Installed between ‘Z’ bars or wood battens on 600 mm (24") centres. | ||
;(6) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLOSURE |'''Pre-formed Foam Closures''']]: Set in accepted caulking. | ;(6) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLOSURE |'''Pre-formed Foam Closures''']]: Set in accepted caulking. |
Revision as of 18:23, 10 August 2016
1 WORK INCLUDED
- (1) Underlayment
- The type of underlay required is determined by roof slope.
- (2) Insulation Overlay Protection
- Recommended.
- (3) Architectural Metal Roof Panel
- Turn up (bread panned) at termination.
- (4) 'Z'-Bar
- Installed to meet adequate attachment for UL I-90 wind uplift requirements.
- (5) Insulation
- Installed between ‘Z’ bars or wood battens on 600 mm (24") centres.
- (6) Pre-formed Foam Closures
- Set in accepted caulking.
- (7) Exposed Fasteners
- High domed, gasketed cladding type screws compatible with metal roof panel.
- (8) Metal Cap Flashing
- Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2").
- (9) Drag-load Fasteners
- Compatible non-corrosive fasteners.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.