=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
 
+
;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope.  
(1) <b>Underlayment</b>: The type of underlay required is determined by roof slope (see Section 8.1.4.1 and Section 8.1.4.2).  
+
;(2) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMSLIP|'''Slip Sheet''']]: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.  
 
+
;(7) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMPANEL |'''Architectural Metal Roof Panel''']] : Turn up (bread panned) at termination and drag load fastened with compatible non-corrosive fasteners.  
(2) <b>Slip Sheet</b>: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.  
+
;(4) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLIP|'''Metal Panel Clip''']]: Installed to metal roof panel manufacturer's printed instructions.  
 
+
;(5) ''''Z'-Bar Closure''': Set in accepted caulking and secured with compatible non-corrosive flat head fasteners.  
(3) <b>Architectural Metal Roof Panel</b>: Turn up (bread panned) at termination and drag load fastened with compatible non-corrosive fasteners.  
+
;(6) '''Perforated Metal Screen'''
 
+
;(7) '''Continuous Cleat'''
(4) <b>Metal Panel Clip</b>: Installed to metal roof panel manufacturer&#8217;s printed instructions.  
+
;(8) '''Metal Cap Flashing''': Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under.
 
 
(5) <b>&#8216;Z&#8217; Closure</b>: Set in accepted caulking and secured with compatible non-corrosive flat head fasteners.  
 
 
 
(6) <b>Perforated Metal Screen</b>
 
 
 
(7) <b>Continuous Cleat</b>
 
 
 
(8) <b>Metal Cap Flashing</b>: Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under.
 
  
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
 +
;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']]
 +
;(B) '''Wood Nailer'''
 +
;(C) '''Air Space''': Determined by Design Authority.
  
(A) <b>Acceptable Deck</b>
 
 
(B) <b>Wood Nailer</b>
 
 
(C) <b>Air Space</b>: Determined by Design Authority.
 
 
 
'''NOTE''': Refer to <i>RGC Guarantee Standards</i> for additional requirements.
 
  
 +
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
  
 
<hr>
 
<hr>
Line 38: Line 25:
  
  
 +
[[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Application'']]
  
[[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''ASM Application'']]
+
[[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']]
 
 
[[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''ASM Construction Details'']]
 
  
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Construction Details'']]
+
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]

Revision as of 18:24, 10 August 2016

8.1.4.13.1.jpg


1 WORK INCLUDED

(1) Underlayment
The type of underlay required is determined by roof slope.
(2) Slip Sheet
Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(7) Architectural Metal Roof Panel 
Turn up (bread panned) at termination and drag load fastened with compatible non-corrosive fasteners.
(4) Metal Panel Clip
Installed to metal roof panel manufacturer's printed instructions.
(5) 'Z'-Bar Closure
Set in accepted caulking and secured with compatible non-corrosive flat head fasteners.
(6) Perforated Metal Screen
(7) Continuous Cleat
(8) Metal Cap Flashing
Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under.


2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Wood Nailer
(C) Air Space
Determined by Design Authority.


NOTE: Refer to RoofStar Guarantee Standards for additional requirements.