Difference between revisions of "ASM Cylindrical Penetration (Flexible Boot Flashing)"
Difference between revisions of "ASM Cylindrical Penetration (Flexible Boot Flashing)"
(→WORK INCLUDED) |
|||
Line 1: | Line 1: | ||
− | [[File:8.1.4.8.1.jpg]] | + | <div class="panel panel-success"> |
− | + | <div class="panel-heading"><big>'''ASM Details'''</big></div> | |
+ | <div class="panel-body"> | ||
+ | <div class="col-md-6"> | ||
+ | <div style="text-align:center; vertical-align:center"> | ||
+ | [[File:8.1.4.8.1.jpg|class=img-responsive]] | ||
+ | </div> | ||
+ | </div><!-- COL-MD-6 --> | ||
+ | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope. | ;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope. | ||
Line 20: | Line 27: | ||
;(C) '''Opening In Roof Deck''': Must be large enough to allow for thermal movement of metal roof panels. | ;(C) '''Opening In Roof Deck''': Must be large enough to allow for thermal movement of metal roof panels. | ||
;(D) '''Pipe Or Support Stand''' | ;(D) '''Pipe Or Support Stand''' | ||
− | + | </div><!-- COL-6-MD --> | |
+ | </div><!-- PANEL BODY --> | ||
+ | </div><!-- PANEL --> | ||
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements. | '''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements. |
Revision as of 20:30, 19 August 2016
ASM Details
1 WORK INCLUDED
- (1) Underlayment
- The type of underlay required is determined by roof slope.
- (2) Slip Sheet
- Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
- (3) Architectural Metal Roof Panel
- (4) Flange
- Set in two continuous beads of accepted caulking.
- (5) Preformed Penetration Collar
- (6) High-domed Gasketed Cladding-type Screws
- Flange fastened to manufacturer.s specifications.
- (7) Seal Between Pipe And Flashing
- Continuous tooled bead of accepted caulking.
- (8) Stainless Steel Drawband
- (9) Water Tight Back Up Storm Collar
- Installed where practical.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Location Of Penetrations
- Must not interfere with standing seams or trapezoidal and intermediate ribs.
- (C) Opening In Roof Deck
- Must be large enough to allow for thermal movement of metal roof panels.
- (D) Pipe Or Support Stand
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.