=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
 
;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope.  
 
;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope.  
Line 17: Line 24:
 
;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']]
 
;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']]
 
;(B) '''Wood Curb''': 200 mm (8") minimum height  
 
;(B) '''Wood Curb''': 200 mm (8") minimum height  
 
+
</div><!-- COL-6-MD -->
 +
</div><!-- PANEL BODY -->
 +
</div><!-- PANEL -->
  
 
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
 
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.

Revision as of 20:31, 19 August 2016

ASM Details

ASM 11.2.1 Curb, Split Panel.jpg

1 WORK INCLUDED

(1) Underlayment
The type of underlay required is determined by roof slope.
(2) Slip Sheet
Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(3) Metal Panel Clip
Installed to metal roof panel manufacturer's printed instructions.
(4) Architectural Metal Roof Panel
(5) Metal Curb Flashing
(6) Cricket
Required for curbs more than 900 mm (36") wide
(7) Acceptable Caulking
Two rows accepted caulking between overlapping sheets, with preformed closures on trapezoidal ribbed roof panels.
(8) Metal Counter Flashing

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Wood Curb
200 mm (8") minimum height

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.