Difference between revisions of "TS Details:E4.7.5 (Tile - Curb Flashing)"
Difference between revisions of "TS Details:E4.7.5 (Tile - Curb Flashing)"
(Created page with "<hr> Curb flashings are applied around skylights, chimneys or other larger penetrations. The basic principle is to deflect the water rushing against the uproof side, safely a...") |
|||
Line 1: | Line 1: | ||
− | |||
Curb flashings are applied around skylights, chimneys or other larger penetrations. The basic principle is to deflect the water rushing against the uproof side, safely around then on top of the tiles on the down roof side. | Curb flashings are applied around skylights, chimneys or other larger penetrations. The basic principle is to deflect the water rushing against the uproof side, safely around then on top of the tiles on the down roof side. | ||
The recommended method is to use 3 lb. lead sheeting due to its malleability and, therefore, easy conformance to the tile’s contour. | The recommended method is to use 3 lb. lead sheeting due to its malleability and, therefore, easy conformance to the tile’s contour. | ||
− | [[File:7.3.2.2.17.jpg]] | + | <div class="panel panel-success"> |
+ | <div class="panel-heading"><big>'''Tile Roofing Details'''</big></div> | ||
+ | <div class="panel-body"> | ||
+ | <div class="col-md-6"> | ||
+ | <div style="text-align:center; vertical-align:center"> | ||
+ | [[File:7.3.2.2.17.jpg|class=img-responsive]] | ||
+ | </div> | ||
+ | </div><!-- COL-MD-6 --> | ||
+ | |||
+ | <div class="col-md-6"> | ||
Upper and lower flashings should be conformed with tile’s surface. | Upper and lower flashings should be conformed with tile’s surface. | ||
Line 13: | Line 21: | ||
A mortar or mastic bedding should be applied to the tops of the concrete tile before flashing to prevent wind blown rain or vermin from entering. | A mortar or mastic bedding should be applied to the tops of the concrete tile before flashing to prevent wind blown rain or vermin from entering. | ||
+ | </div><!-- COL-6-MD --> | ||
+ | </div><!-- PANEL BODY --> | ||
+ | </div><!-- PANEL --> | ||
<hr> | <hr> | ||
+ | [[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Slate Application'']] | ||
− | + | [[Tile and Slate Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Tile and Slate Construction Details'']] | |
− | |||
− | [[Tile and Slate Construction Details|<i class="fa fa-chevron-circle-left fa | ||
− | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']] |
Revision as of 21:08, 19 August 2016
Curb flashings are applied around skylights, chimneys or other larger penetrations. The basic principle is to deflect the water rushing against the uproof side, safely around then on top of the tiles on the down roof side.
The recommended method is to use 3 lb. lead sheeting due to its malleability and, therefore, easy conformance to the tile’s contour.
Tile Roofing Details
Upper and lower flashings should be conformed with tile’s surface.
- Upper flashings should extend 150 mm (6") past corners on each side, then formed around soakers.
- Lower flashing should extend 100 mm (4") past corners and lapped under the soakers.
A mortar or mastic bedding should be applied to the tops of the concrete tile before flashing to prevent wind blown rain or vermin from entering.