=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | (1) <b>Metal Cant Flashing:</b> Standing seam required at corners of cant. See | + | (1) <b>Metal Cant Flashing:</b> Standing seam required at corners of cant. See [[RoofStar Guarantee Standards for SBS Roof Systems#SBSMETALSEAM|'''SBS Roof Systems - 12.5 Seams''']]. |
− | (2) <b>Metal Base Flashing:</b> Vertical runs over 100 mm (4") require standing seam or S-lock corners. See | + | (2) <b>Metal Base Flashing:</b> Vertical runs over 100 mm (4") require standing seam or S-lock corners. See [[RoofStar Guarantee Standards for SBS Roof Systems#SBSMETALBASE|'''SBS Roof Systems - 12.6 Cap Flashings, Base Flashings and Reglets''']]. Cross-breaks and cladding-type fasteners are optional. |
− | (3) <b>Double </b><b>S-Lock Corner</b>: Fastened through concealed flanges to top of parapet. | + | (3) <b>Double </b><b>S-Lock Corner</b>: Fastened through concealed flanges to top of parapet. Again, see [[RoofStar Guarantee Standards for SBS Roof Systems#SBSMETALSEAM|'''SBS Roof Systems - 12.5 Seams''']]. |
− | (4) <b>Metal Cap Flashing – Interior Face:</b> Fastened with continuous clips or cladding screws evenly spaced between seams. Over 100 mm (4") width requires standing seam. See | + | (4) <b>Metal Cap Flashing – Interior Face:</b> Fastened with continuous clips or cladding screws evenly spaced between seams. Over 100 mm (4") width requires standing seam. See [[RoofStar Guarantee Standards for SBS Roof Systems#SBSMETALBASE|'''SBS Roof Systems - 12.6 Cap Flashings, Base Flashings and Reglets''']] for requirements. |
− | (5) <b>Seam:</b> Lap seam is acceptable if vertical distance is not more than 100 mm (4"). | + | (5) <b>Seam:</b> Lap seam is acceptable if vertical distance is not more than 100 mm (4"). Again see [[RoofStar Guarantee Standards for SBS Roof Systems#SBSMETALSEAM|'''SBS Roof Systems - 12.5 Seams''']]. |
− | (6) <b>Metal Cap Flashing – Top Face:</b> Over 100 mm (4") width must provide positive slope to roof area. | + | (6) <b>Metal Cap Flashing – Top Face:</b> Over 100 mm (4") width must provide positive slope to roof area. |
(7) <b>Standing Seam</b> | (7) <b>Standing Seam</b> | ||
− | (8) <b>Metal Cap Flashing – Outside Face:</b> Corner standing seams may be folded flat on outside face only. Fasten with continuous concealed clip-type fasteners <b>or</b> cladding screws evenly spaced between seams. | + | (8) <b>Metal Cap Flashing – Outside Face:</b> Corner standing seams may be folded flat on outside face only. Fasten with continuous concealed clip-type fasteners <b>or</b> cladding screws evenly spaced between seams. |
Line 30: | Line 33: | ||
(A) <b>Acceptable Parapet</b> | (A) <b>Acceptable Parapet</b> | ||
− | (B) <b>Sloped Blocking: </b> Required over minimum 100 mm (4") parapet width. See | + | (B) <b>Sloped Blocking: </b> Required over minimum 100 mm (4") parapet width. See [[RoofStar Guarantee Standards for SBS Roof Systems#SBSMETALFLASH|'''SBS Roof Systems - 12. Perimeter Flashing: Metal''']] |
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> |
Revision as of 17:01, 1 September 2016
RoofStar Guarantee Standards are blue-linked |
1 WORK INCLUDED
(1) Metal Cant Flashing: Standing seam required at corners of cant. See SBS Roof Systems - 12.5 Seams.
(2) Metal Base Flashing: Vertical runs over 100 mm (4") require standing seam or S-lock corners. See SBS Roof Systems - 12.6 Cap Flashings, Base Flashings and Reglets. Cross-breaks and cladding-type fasteners are optional.
(3) Double S-Lock Corner: Fastened through concealed flanges to top of parapet. Again, see SBS Roof Systems - 12.5 Seams.
(4) Metal Cap Flashing – Interior Face: Fastened with continuous clips or cladding screws evenly spaced between seams. Over 100 mm (4") width requires standing seam. See SBS Roof Systems - 12.6 Cap Flashings, Base Flashings and Reglets for requirements.
(5) Seam: Lap seam is acceptable if vertical distance is not more than 100 mm (4"). Again see SBS Roof Systems - 12.5 Seams.
(6) Metal Cap Flashing – Top Face: Over 100 mm (4") width must provide positive slope to roof area.
(7) Standing Seam
(8) Metal Cap Flashing – Outside Face: Corner standing seams may be folded flat on outside face only. Fasten with continuous concealed clip-type fasteners or cladding screws evenly spaced between seams.
2 RELATED WORK BY OTHERS
(A) Acceptable Parapet
(B) Sloped Blocking: Required over minimum 100 mm (4") parapet width. See SBS Roof Systems - 12. Perimeter Flashing: Metal
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.