Revision as of 01:11, 15 September 2016
The drawings contained within this section are intended to represent a variety of modified bituminous roof system applications while remaining generic with regards to manufacturers’ specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult manufacturers’ specifications and RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and RGC.
For further information about SBS membrane system design and requirements, see SBS Roof Systems.
- D1.7.1 Assemblies (Insulated Conventional)
- D1.7.2 Assemblies (Protected Membrane)
- D1.7.3 Parapets & Copings (Low Parapet - Wall Supported)
- D1.7.4 Parapets & Copings (Low Parapet - Unsupported by Wall)
- D1.7.5 Parapets & Copings (High Parapet - Wall Supported)
- D1.7.6 Parapets & Copings (Parapet - Wall Transition)
- D1.7.7 Edges & Fascia (Cant Edge)
- D1.7.8 Edges & Fascia (Gravel Stop)
- D1.7.9 Counter-flashings & Reglets (Deck - Wall Supported)
- D1.7.10 Counter-flashings & Reglets (Deck - Unsupported by Wall)
- D1.7.11 Counter-flashings & Reglets (Stucco Wall: Re-roofing)
- D1.7.12 Counter-flashings & Reglets (Stucco Wall: New)(Under Construction)
- D1.7.13 Counter-flashings & Reglets (Double Surface Reglet)
- D1.7.14 Counter-flashings & Reglets (Low Door Sill)
- D1.7.15 Counter-flashings & Reglets (Window Curb)
- D1.7.16 Roof-Wall Transitions (Expansion Joint)
- D1.7.17 Roof-Wall Transitions (Divider/Control Joint)
- D1.7.18 Roof-Wall Transitions (Fire Separation Joint)
- D1.7.19 Roof-Wall Transitions (Fire Separation Wall)
- D1.7.20 Curbs & Sleepers (Equipment Sleeper)
- D1.7.21 Curbs & Sleepers (Multiple Roof Penetrations)
- D1.7.22 Curbs & Sleepers (Basic Curb)
- D1.7.23 Curbs & Sleepers (Mechanical Opening)
- D1.7.24 Curbs & Sleepers (Pre-curb for Planters)
- D1.7.25 Strip-in Flashings (Metal Plumbing)
- D1.7.26 Strip-in Flashings (Two-part Cable)
- D1.7.27 Strip-in Flashings (Gum Pan/Pitch Pocket)
- D1.7.28 Water & Drainage (Cast Iron Drain)
- D1.7.29 Water & Drainage (Spun Copper Drain)
- D1.7.30 Water & Drainage (Clamping Spun Copper Drain)
- D1.7.31 Water & Drainage (Open Wall Scupper)
- D1.7.32 Water & Drainage (Through-wall Scupper)
- D1.7.33 Miscellaneous Penetrations (Roof Anchor)
- D1.7.34 Miscellaneous Penetrations (Wall Anchor - Conventional Roof Assy)
- D1.7.35 Miscellaneous Penetrations (Wall Anchor - Protected Roof Assy)
- D1.7.36 Miscellaneous Penetrations (Guardrails)