|+ How to use the table:
 
 
 
#In the table below look for <u>maximum wind uplift values that exceed</u> the requirements determined through the RCI calculator;<p>('''NOTE''': while the reports show two different values for tested maximum assembly strength, the RPM tables display only the values adjusted for the required safety factor of 1.5)</p>
 
#Open the report for the tested assembly that fits with the design parameters you have chosen and calculated, and examine the report.  It will break down the assembly by its components.  Ensure all the key components (Secondary materials, such as deck overlay, insulation and insulation overlay) are accepted by the '''''RoofStar Guarantee Program''''' (note that fasteners and adhesives currently are not listed in this Manual - use the materials specified in the wind test report, or consult the membrane manufacturer);
 
#In cases where a tested Secondary material is not accepted by the '''''RoofStar Guarantee Program''''', look for alternates which often are published in the each report.  In the absence of published alternates, locate a possible alternate in the [http://rpm.rcabc.org/index.php?title=Materials_by_Product_Type '''Accepted Materials'''] section of this Manual.  If you are unsure about compatibility, contact the [mailto:guarantees@rcabc.org '''RCABC'''].
 
 
! style="vertical-align:top;" | Manufacturer
 
! style="vertical-align:top;" | Manufacturer
 
! style="vertical-align:top;" | Product Name
 
! style="vertical-align:top;" | Product Name
Line 22: Line 17:
 
|| '''[[Carlisle Syntec Systems Canada]]''' || [[Materials:Sure-Flex 50 mil PVC Membrane|Sure-Flex 50 mil PVC Membrane]] || style="text-align:center;"| 1 Tested System<br>1 Tested System || style="text-align:center;"| ----<br>---- || style="text-align:center;"| -3.40<br>-2.30 || style="text-align:center;"| ----<br>---- || style="text-align:center;"| -70.00<br>-47.00 || style="text-align:center;"| Steel<br>Steel || style="text-align:center;"| [http://rpm.rcabc.org/images/d/d2/CAR-MARS1.pdf '''MARS Test Report 1''']<br>[http://rpm.rcabc.org/images/9/94/CAR-MARS2.pdf '''MARS Test Report 2'''] || style="text-align:center;"| exp. Service Inc. || style="text-align:center;"| PUB-CRU237226<br>RAP-DRU208111
 
|| '''[[Carlisle Syntec Systems Canada]]''' || [[Materials:Sure-Flex 50 mil PVC Membrane|Sure-Flex 50 mil PVC Membrane]] || style="text-align:center;"| 1 Tested System<br>1 Tested System || style="text-align:center;"| ----<br>---- || style="text-align:center;"| -3.40<br>-2.30 || style="text-align:center;"| ----<br>---- || style="text-align:center;"| -70.00<br>-47.00 || style="text-align:center;"| Steel<br>Steel || style="text-align:center;"| [http://rpm.rcabc.org/images/d/d2/CAR-MARS1.pdf '''MARS Test Report 1''']<br>[http://rpm.rcabc.org/images/9/94/CAR-MARS2.pdf '''MARS Test Report 2'''] || style="text-align:center;"| exp. Service Inc. || style="text-align:center;"| PUB-CRU237226<br>RAP-DRU208111
 
|-
 
|-
|| '''[[Johns Manville Corporation]]''' || [[Materials:JM PVC (60 mil.) |JM PVC (60 mil.)]] || style="text-align:center;"| 1 Tested System || style="text-align:center;"| - || style="text-align:center;"| -3.60 || style="text-align:center;"| - || style="text-align:center;"| -75.0 || style="text-align:center;"| - || style="text-align:center;"| [http://rpm.rcabc.org/images/9/96/JM-MARS2.pdf '''MARS Test Report 2'''] || style="text-align:center;"| exp. Service Inc. || style="text-align:center;"| PUB-DRU292249
+
|| '''[[Johns Manville Corporation]]''' || [[Materials:JM PVC (60 mil.) |JM PVC (60 mil.)]] || style="text-align:center;"| 1 Tested System || style="text-align:center;"| ---- || style="text-align:center;"| -3.60 || style="text-align:center;"| ---- || style="text-align:center;"| -75.0 || style="text-align:center;"| Steel || style="text-align:center;"| [http://rpm.rcabc.org/images/2/27/JM-MARS1.pdf '''MARS Test Report 1'''] || style="text-align:center;"| exp. Service Inc. || style="text-align:center;"| PUB-DRU292249
 
|-
 
|-
|| '''[[Johns Manville Corporation]]''' || [[Materials:JM PVC (80 mil.) |JM PVC (80 mil.)]] || style="text-align:center;"| 1 Tested System || style="text-align:center;"| - || style="text-align:center;"| -3.60 || style="text-align:center;"| - || style="text-align:center;"| -75.0 || style="text-align:center;"| - || style="text-align:center;"| [http://rpm.rcabc.org/images/9/96/JM-MARS2.pdf '''MARS Test Report 2'''] || style="text-align:center;"| exp. Service Inc. || style="text-align:center;"| PUB-DRU292249
+
|| '''[[Johns Manville Corporation]]''' || [[Materials:JM PVC (80 mil.) |JM PVC (80 mil.)]] || style="text-align:center;"| 1 Tested System || style="text-align:center;"| ---- || style="text-align:center;"| -3.60 || style="text-align:center;"| ---- || style="text-align:center;"| -75.0 || style="text-align:center;"| Steel || style="text-align:center;"| [http://rpm.rcabc.org/images/9/96/JM-MARS2.pdf '''MARS Test Report 2'''] || style="text-align:center;"| exp. Service Inc. || style="text-align:center;"| PUB-DRU292249
 
|-
 
|-
 
|}
 
|}
 
   </table>
 
   </table>
 
</div>
 
</div>

Latest revision as of 18:55, 15 April 2020

Manufacturer Product Name Number of Tested Systems
(per report)
kPa (Low) kPa (High) Psf (Low) Psf (High) Deck Type Downloadable Test Report Test Facility Test Facility Report No.
Carlisle Syntec Systems Canada Sure-Flex 50 mil PVC Membrane 1 Tested System
1 Tested System
----
----
-3.40
-2.30
----
----
-70.00
-47.00
Steel
Steel
MARS Test Report 1
MARS Test Report 2
exp. Service Inc. PUB-CRU237226
RAP-DRU208111
Johns Manville Corporation JM PVC (60 mil.) 1 Tested System ---- -3.60 ---- -75.0 Steel MARS Test Report 1 exp. Service Inc. PUB-DRU292249
Johns Manville Corporation JM PVC (80 mil.) 1 Tested System ---- -3.60 ---- -75.0 Steel MARS Test Report 2 exp. Service Inc. PUB-DRU292249