:<big>2-Part Component Systems</big> | :<big>2-Part Component Systems</big> | ||
− | :For use with | + | :For use with fabric reinforcement only (refer to product '''Technical Data Sheet''' for proprietary reinforcement materials). These systems may be used on or within 200 mm (8") of the water plane. |
{| class="wikitable sortable" style="margin-left: 20pt; margin-right: auto; border: none;" | {| class="wikitable sortable" style="margin-left: 20pt; margin-right: auto; border: none;" | ||
|+ Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program | |+ Click on a manufacturer's name to see the full list of their products accepted for use in the RoofStar Guarantee Program | ||
Line 14: | Line 14: | ||
! style="vertical-align:top;" | Special Notes | ! style="vertical-align:top;" | Special Notes | ||
|- | |- | ||
− | || '''[[Firestone | + | || '''[[Manufacturers:Elevate | Elevate (fomerly Firestone)]]''' || [[Materials:Ultraflash|Ultraflash]] || style="text-align:center;"| Organo-silane compound paired with polyester scrim || style="text-align:center;"| See Manufacturer || style="text-align:center;"| Refer to Technical Data Sheet |
|- | |- | ||
− | || '''[[ | + | || '''[[Manufacturers:Henry Company Canada | Henry Company Canada]]''' || [[Materials:Pumadeq Flex 31MV | Pumadeq Flex 31MV]] || style="text-align:center;"| Catalyzed polyurethane methyl methacrylate used with N-Fleece fabric reinforcement || style="text-align:center;"| See Manufacturer || style="text-align:center;"| Refer to Technical Data Sheet |
|- | |- | ||
− | || '''[[ | + | || '''[[Manufacturers:IKO Industries Ltd. | IKO Industries Ltd.]]''' || [[Materials:Metatech Flashing | {{hilite | Metatech Flashing || 2025-January-31 }}]] || style="text-align:center;"| Catalyzed polyurethane methyl methacrylate used with N-Fleece fabric reinforcement || style="text-align:center;"| See Manufacturer || style="text-align:center;"| Refer to Technical Data Sheet |
|- | |- | ||
− | || '''[[Soprema Inc.]]''' || [[Materials:Alsan RS System|Alsan RS System]] || style="text-align:center;"| 2-part liquid paired with Alsan RS Fleece || style="text-align:center;"| See Manufacturer || style="text-align:center;"| Refer to Technical Data Sheet | + | || '''[[Manufacturers:Johns Manville Corporation | Johns Manville Corp.]]''' || [[Materials:PermaFlash|PermaFlash]] || style="text-align:center;"| MBR® Flashing Cement used with polyester reinforcement || style="text-align:center;"| See Manufacturer || style="text-align:center;"| Refer to Technical Data Sheet |
+ | |- | ||
+ | || '''[[Manufacturers:Siplast, Inc. | Siplast, Inc.]]''' || [[Materials:Parapro 123 Flashing Resin |Parapro 123 Flashing Resin]] || style="text-align:center;"| 2-part resin available in summer and winter grades || style="text-align:center;"| See Manufacturer || style="text-align:center;"| Refer to Technical Data Sheet | ||
+ | |- | ||
+ | || '''[[Manufacturers:Soprema Inc. | Soprema Inc.]]''' || [[Materials:Alsan RS System|Alsan RS System]] || style="text-align:center;"| 2-part liquid paired with Alsan RS Fleece || style="text-align:center;"| See Manufacturer || style="text-align:center;"| Refer to Technical Data Sheet | ||
|- | |- | ||
|} | |} | ||
− | + | ||
− | |||
− | |||
:<hr> | :<hr> | ||
:<big>Single-component Systems</big> | :<big>Single-component Systems</big> | ||
Line 37: | Line 39: | ||
! style="vertical-align:top;" | Special Notes | ! style="vertical-align:top;" | Special Notes | ||
|- | |- | ||
− | || '''[[IKO Industries Ltd.]]''' || [[Materials: | + | || '''[[Manufacturers:IKO Industries Ltd. | IKO Industries Ltd.]]''' || [[Materials:MS Detail| MS Detail]] || style="text-align:center;"| single-component flashing || style="text-align:center;"| See Manufacturer || style="text-align:center;"| See notations on Material page |
|- | |- | ||
− | || '''[[Polyglass USA, Inc.]]''' || [[Materials:Polyflash 1C|Polyflash 1C]] || style="text-align:center;"| single-component moisture-cured || style="text-align:center;"| See Manufacturer || style="text-align:center;"| To be used only with Polyglass membranes | + | || '''[[Manufacturers:Polyglass USA, Inc. | Polyglass USA, Inc.]]''' || [[Materials:Polyflash 1C|Polyflash 1C]] || style="text-align:center;"| single-component moisture-cured || style="text-align:center;"| See Manufacturer || style="text-align:center;"| To be used only with Polyglass membranes |
|- | |- | ||
− | || '''[[Soprema Inc.]]''' || [[Materials:Alsan Flashing|Alsan Flashing]] || style="text-align:center;"| Single component polyurethane/bitumen coating || style="text-align:center;"| See Manufacturer || style="text-align:center;"| See notations on Material page | + | || '''[[Manufacturers:Soprema Inc. | Soprema Inc.]]''' || [[Materials:Alsan Flashing|Alsan Flashing]] || style="text-align:center;"| Single component polyurethane/bitumen coating || style="text-align:center;"| See Manufacturer || style="text-align:center;"| See notations on Material page |
|- | |- | ||
|} | |} |
Latest revision as of 14:16, 23 September 2024
- Note to Reader
- Liquid membrane flashing systems are manufactured from various bituminous and non-bituminous materials. These manufactured proprietary flashing systems are specifically designed for use to flash unusual roof penetration shapes or roof details that are difficult to flash with traditional membranes.
- Liquid membrane flashings are available as one or two part component systems that require reinforcement scrims for strength. To ensure quality installation, manufacturers’ proprietary application instructions must be strictly followed.
- 2-Part Component Systems
- For use with fabric reinforcement only (refer to product Technical Data Sheet for proprietary reinforcement materials). These systems may be used on or within 200 mm (8") of the water plane.
Manufacturer | Product / System Name | Description / Features | Applicator Training | Special Notes |
---|---|---|---|---|
Elevate (fomerly Firestone) | Ultraflash | Organo-silane compound paired with polyester scrim | See Manufacturer | Refer to Technical Data Sheet |
Henry Company Canada | Pumadeq Flex 31MV | Catalyzed polyurethane methyl methacrylate used with N-Fleece fabric reinforcement | See Manufacturer | Refer to Technical Data Sheet |
IKO Industries Ltd. | Metatech Flashing | Catalyzed polyurethane methyl methacrylate used with N-Fleece fabric reinforcement | See Manufacturer | Refer to Technical Data Sheet |
Johns Manville Corp. | PermaFlash | MBR® Flashing Cement used with polyester reinforcement | See Manufacturer | Refer to Technical Data Sheet |
Siplast, Inc. | Parapro 123 Flashing Resin | 2-part resin available in summer and winter grades | See Manufacturer | Refer to Technical Data Sheet |
Soprema Inc. | Alsan RS System | 2-part liquid paired with Alsan RS Fleece | See Manufacturer | Refer to Technical Data Sheet |
- Single-component Systems
- (NOTE: these flashing systems have limited application within the RoofStar Guarantee Program, and may be used on upstand angles, support junctions and joints that are typically more than 200 mm (8") above water plane. These materials may also be used as a coating on galvanized flashings and other strip-in flashings requiring a coating (see RoofStar Guarantee Standards for SBS-modified Bitumen Roof Assemblies, 12.4 Strip-in Flashings)
Manufacturer | Product / System Name | Description / Features | Applicator Training | Special Notes |
---|---|---|---|---|
IKO Industries Ltd. | MS Detail | single-component flashing | See Manufacturer | See notations on Material page |
Polyglass USA, Inc. | Polyflash 1C | single-component moisture-cured | See Manufacturer | To be used only with Polyglass membranes |
Soprema Inc. | Alsan Flashing | Single component polyurethane/bitumen coating | See Manufacturer | See notations on Material page |