Difference between revisions of "Materials:Ultraflash"
Difference between revisions of "Materials:Ultraflash"
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
+ | __NOTOC__ | ||
+ | __NONUMBEREDHEADINGS__ | ||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | |||
+ | <big><big>Division C - Accepted Materials</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>Elevate UltraFlash Two-Part Liquid Flashing System</big></big></big></big></big><br> | ||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
| style="background-color: #ffffcc; column-width:100%" | '''Notice to the Reader''': | | style="background-color: #ffffcc; column-width:100%" | '''Notice to the Reader''': | ||
− | The | + | The information published in the RCABC '''''Roofing Practices Manual''''' and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this material recommended or endorsed by the ''Guarantor''. The preparation of a detailed specification is the responsibility of the ''Design Authority''. |
|} | |} | ||
+ | |||
{| class="wikitable" | {| class="wikitable" | ||
|- | |- | ||
− | | '''Manufacturer | + | | '''<big>Manufacturer and Acceptance</big>''' |
− | |||
− | |||
;: | ;: | ||
− | ;''' | + | ;'''Manufacturer''': [https://holcimelevate.com/ca-en '''Elevate Commercial Roofing Systems'''] |
− | + | ;Accepted for the ''RoofStar Guarantee Program'': June 2011 | |
− | + | ;Accepted for application in: Waterproofing Roof Systems<br>Grade-level Waterproofing Systems | |
− | + | ;Product Summary: '''Elevate UltraFlash Two-Part Liquid Flashing System''' is a flexible flashing system specially designed to work with a variety of bituminous roofing systems to ensure the weatherproofing of a wide range of details. It is a liquid applied two part system consisting of a stitch-bonded polyester scrim (UltraFlash Fabric) and UltraFlash Liquid Flashing for superior bonding and durability. UltraFlash Primer can be used to improve the adhesion of the flashing system to its substrate. | |
− | |||
− | |||
− | |||
− | : | + | :'''Elevate UltraFlash Two-Part Liquid Flashing System''' requires a blend of Part A and Part B activator to form an impermeable, seamless, monolithic membrane. The material cures chemically at ambient temperature to form a tack free polyurethane elastomer within approximately four hours. It is intended for use with SBS modified bitumen, APP granule surfaced and BUR roofing systems. Application is recommended for vertical surfaces such as flashing walls and curbs, penetrations, roof drains, penetration pockets with pipe clusters and unusual shaped penetrations. UltraFlash Liquid Flashing adheres to concrete, steel, glass, wood and most surfaces. |
− | : | + | :'''UltraFlash Primer''' is an organo-silane compound dispersed in isopropyl alcohol. For best adhesion use UltraFlash Primer on all nonporous surfaces including all metal surfaces. UltraFlash Liquid Flashing must be applied within one hour of the application of UltraFlash Primer. If more than one hour has elapsed from initial application, reapply UltraFlash Primer. |
− | |||
− | |||
− | |||
− | |||
− | |||
− | : | + | :'''UltraFlash Fabric''' is a stitchbonded polyester scrim that provides a sturdy combination of burst strength and toughness for roofing applications. This flexible polyester allows elongation up to 50%, easily supporting against thermal stresses and movements. |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | : | + | :Mixing '''Elevate UltraFlash Two-Part Liquid Flashing System''' can be done in the original 19 litre (5 gallon) containers for 3 minutes. For those who prefer a method other than mixing, UltraFlash Liquid Flashing Dual Cartridges are also available. These cartridges contain the two component adhesive and require the use of an applicator and static mixer. (adapted from the Technical Data Sheet) |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | : | + | ;Conditions and Limitations: None |
|} | |} | ||
Line 131: | Line 36: | ||
<div class="col-md-2"> | <div class="col-md-2"> | ||
− | :[[File:Pdf.png| | + | :[[File:Pdf.png|100 px|link=https://rpm.rcabc.org/images/3/35/Elevate_UltraFlash_Two-Part_Liquid_Flashing_TDS.pdf|'''Elevate UltraFlash 2-Part Liquid Flashing - Technical Data Sheet''']] |
<div style="text-align: center;"> | <div style="text-align: center;"> | ||
:UltraFlash 2-Part Liquid Flashing TDS | :UltraFlash 2-Part Liquid Flashing TDS | ||
Line 137: | Line 42: | ||
</div> | </div> | ||
<div class="col-md-2"> | <div class="col-md-2"> | ||
− | :[[File:Pdf.png| | + | :[[File:Pdf.png|100 px|link=https://rpm.rcabc.org/images/5/55/Elevate_UltraFlash_Fabric_TDS.pdf|'''UltraFlash Fabric - Technical Data Sheet''']] |
<div style="text-align: center;"> | <div style="text-align: center;"> | ||
:UltraFlash Fabric TDS | :UltraFlash Fabric TDS | ||
+ | </div> | ||
+ | </div> | ||
+ | <div class="col-md-2"> | ||
+ | :[[File:Pdf.png|100 px|link=https://rpm.rcabc.org/images/3/35/Elevate_UltraFlash_LVOC_Primer_TDS.pdf|'''UltraFlash LVOC Primer - Technical Data Sheet''']] | ||
+ | <div style="text-align: center;"> | ||
+ | :UltraFlash LVOC Primer TDS | ||
</div> | </div> | ||
</div> | </div> | ||
Line 146: | Line 57: | ||
<hr> | <hr> | ||
− | [[Materials | + | [[Division C: Accepted Materials|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Accepted Materials'']] |
− | |||
[[Main Page|Home]] | [[Main Page|Home]] | ||
− |
Latest revision as of 15:41, 30 May 2024
Division C - Accepted Materials
Elevate UltraFlash Two-Part Liquid Flashing System
Notice to the Reader:
The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this material recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority. |
Manufacturer and Acceptance
|
- Click below for the Technical Data Sheet.