Difference between revisions of "PVC Protected Roof Assembly (Typical)"
Difference between revisions of "PVC Protected Roof Assembly (Typical)"
(2 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
{{Template:RPM Info}} | {{Template:RPM Info}} | ||
+ | |||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | __NOTOC__ | ||
+ | |||
+ | <big><big>Division D - Construction Details</big></big> | ||
<hr> | <hr> | ||
− | + | <big><big><big><big><big>PVC | Protected Membrane Roof Assembly (Typical) ([[PVC_Roof_Systems_Standard#1.1.3.1._Permitted_Roof_Systems | Article 1.1.3.1.]])</big></big></big></big></big> | |
− | + | {{Template:Construction Details Header}} | |
− | | | ||
− | |||
− | |||
<div class="panel panel-success"> | <div class="panel panel-success"> | ||
<div class="panel-heading"><big>'''PVC Details'''</big></div> | <div class="panel-heading"><big>'''PVC Details'''</big></div> | ||
Line 17: | Line 19: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[ | + | ;(1) [[PVC Roof Systems Standard#PART_9|'''Protection Mat''']]: Provide protection between concrete deck and membrane with installation of manufacturer specified and RoofStar-accepted protection mat or deck overlay boards. |
− | ;(2) [[ | + | ;(2) [[PVC Roof Systems Standard#PART_9|'''Single-ply Membrane''']]: Installed according to manufacturer's instructions and ''RoofStar Guarantee Standards''. |
− | ;(3) [[ | + | ;(3) [[PVC Roof Systems Standard#PART_9|'''Adhesive''']]: Proprietary, installed according to manufacturer's instructions, usually brushed, rolled or sprayed. |
− | ;(4) [[ | + | ;(4) [[PVC Roof Systems Standard#PART_9|'''Membrane Lap''']]: Thermoplastic membrane may be welded or chemically bonded. |
;(5) '''Fasteners''': Install according to manufacturer's instructions (may vary from drawing). | ;(5) '''Fasteners''': Install according to manufacturer's instructions (may vary from drawing). | ||
− | ;(6) [[ | + | ;(6) [[PVC Roof Systems Standard#PART_10|'''Membrane Flashing''']]: Adhered according to manufacturer's printed specifications using proprietary adhesive. Must be carried to outside of parapet or minimum 200 mm (8") above finished roof surface. Welded or adhered to primary membrane depending on membrane type. |
− | ;(7) [[ | + | ;(7) [[PVC Roof Systems Standard#PART_7|'''Insulation''']]: Mechanically fastened where deck type permits, or fully adhered (as illustrated). Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. |
− | ;(8) [[ | + | ;(8) [[PVC Roof Systems Standard#PART_12|'''Filter Fabric''']]: Metal [[RoofStar Guarantee Standards for PVC Membrane Systems#PVCMETALBASE|'''Base Flashing''']] required. |
− | ;(9) [[ | + | ;(9) [[PVC Roof Systems Standard#PART_13|'''Metal Flashing''']]: As required by RoofStar Guarantee Standards. |
− | ;(10) [[ | + | ;(10) [[PVC Roof Systems Standard#PART_3|'''Ballast''']]: Gravel or concrete paving tiles. |
− | ;(11) [[ | + | ;(11) [[PVC Roof Systems Standard#PART_10|'''Parapet Flashing''']]: As required by RoofStar Guarantee Standards. |
<hr> | <hr> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[ | + | ;(A) [[PVC Roof Systems Standard#PART_2|'''Acceptable Deck''']] |
− | ;(B) [[ | + | ;(B) [[PVC Roof Systems Standard#PART_10|'''Acceptable Parapet Surface''']]: Surface must be smooth, dry and clean. Rough surface must be covered with treated plywood, to be determined by design authority or inspector or as required by manufacturer. |
− | ;(C) [[ | + | ;(C) [[PVC Roof Systems Standard#PART_13|'''Sloped Wood Blocking''']] |
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> |
Latest revision as of 22:19, 27 June 2022
Division D - Construction Details
PVC | Protected Membrane Roof Assembly (Typical) ( Article 1.1.3.1.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
PVC Details
1 WORK INCLUDED
- (1) Protection Mat
- Provide protection between concrete deck and membrane with installation of manufacturer specified and RoofStar-accepted protection mat or deck overlay boards.
- (2) Single-ply Membrane
- Installed according to manufacturer's instructions and RoofStar Guarantee Standards.
- (3) Adhesive
- Proprietary, installed according to manufacturer's instructions, usually brushed, rolled or sprayed.
- (4) Membrane Lap
- Thermoplastic membrane may be welded or chemically bonded.
- (5) Fasteners
- Install according to manufacturer's instructions (may vary from drawing).
- (6) Membrane Flashing
- Adhered according to manufacturer's printed specifications using proprietary adhesive. Must be carried to outside of parapet or minimum 200 mm (8") above finished roof surface. Welded or adhered to primary membrane depending on membrane type.
- (7) Insulation
- Mechanically fastened where deck type permits, or fully adhered (as illustrated). Installed according to RoofStar Guarantee Standards. See available insulation products in the Accepted Materials section of this Manual.
- (8) Filter Fabric
- Metal Base Flashing required.
- (9) Metal Flashing
- As required by RoofStar Guarantee Standards.
- (10) Ballast
- Gravel or concrete paving tiles.
- (11) Parapet Flashing
- As required by RoofStar Guarantee Standards.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Acceptable Parapet Surface
- Surface must be smooth, dry and clean. Rough surface must be covered with treated plywood, to be determined by design authority or inspector or as required by manufacturer.
- (C) Sloped Wood Blocking
NOTE: See the Standard for additional requirements.
Back to PVC Construction Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.