Rake tiles cover the exposed edge of field tiles at fascia boards. This helps prevent wind driven rain from entering the system and provides an attractive finish. Rake tiles &#8220;butt&#8221; against the lower edge of the field tile courses then are fastened with two nails into the fascia.
 
  
[[File:7.3.2.2.14.jpg]]
+
{{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}}
 +
__NOTOC__
  
<b>Flashings:</b>
+
<big><big>Division D - Construction Details</big></big>
 
+
<hr>
Flashings bridge the gap between field areas and any protrusions such as pipes, vents, and adjoining walls. Because these items impede the flow of water, small deficiencies can cause high amounts of water to enter the building. Proper detail work will make the difference between a successful or problematic roof.
+
<big><big><big><big><big>TS Details:E4.7.2 (Tile - Rake Edge)</big></big></big></big></big>
 
+
{| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
<b>Pipe Flashings:</b>
+
| colspan="2"  | <big>'''''Notice to Reader'''''</big>
 
+
|-
Pipe flashings are made of lead which conforms well to the tiles&#8217; surface. They are applied over the course of tile penetrated by the pipe and under the next course with a 75 mm (3") min. lap.
+
| style="color: black; background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and not prescriptive.  Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the ''Design Authority''.<br><br>The full text of the referenced requirements in the [[Tile Systems Standard | '''Standard''']] may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span>
 
+
|}
[[File:7.3.2.2.15.jpg]]
+
<div class="panel panel-success">
<b>Walls Perpendicular to Slope:</b>
+
<div class="panel-heading"><big>'''Tile Roofing Details'''</big></div>
 
+
<div class="panel-body">
Flashing for a wall termination should lap the tile by a minimum of 100 mm (4"). Material should be the 26 ga. prepainted galvanized with S locks or standing seams to join lengths.
+
<div class="col-md-6">
 
+
<div style="text-align:center; vertical-align:center">
[[File:7.3.2.2.16.jpg]]
+
[[File:7.3.2.2.14.jpg| link=http://rpm.rcabc.org/images/e/ed/7.3.2.2.14.jpg | class=img-responsive]]
 
+
</div>
A mortar or mastic bedding should be applied to the tops of the concrete tile before flashing to prevent wind blown rain or vermin from entering.
+
</div><!-- COL-MD-6 -->
 
 
<b>Curb Flashings:</b>
 
  
Curb flashings are applied around skylights, chimneys or other larger penetrations. The basic principle is to deflect the water rushing against the uproof side, safely around then on top of the tiles on the down roof side.  
+
<div class="col-md-6">
 +
=== WORK INCLUDED ===
 +
;(1) Rake tiles: Rake tiles cover the exposed edge of field tiles at fascia boards. This helps prevent wind driven rain from entering the system and provides an attractive finish. Rake tiles &#8220;butt&#8221; against the lower edge of the field tile courses then are fastened with two nails into the fascia.
  
The recommended method is to use 3 lb. lead sheeting due to its malleability and, therefore, easy conformance to the tile&#8217;s contour.
+
</div><!-- COL-6-MD -->
 +
</div><!-- PANEL BODY -->
 +
</div><!-- PANEL -->
  
[[File:7.3.2.2.17.jpg]]
+
'''NOTE''': See the [[Tile Systems Standard | '''Standard''']] for additional requirements.
 
 
Upper and lower flashings should be conformed with tile&#8217;s surface.Upper flashings should extend 150 mm (6") past corners on each side, then formed around soakers.
 
 
 
Lower flashing should extend 100 mm (4") past corners and lapped under the soakers.
 
  
 
<hr>
 
<hr>
  
 +
[[Tile System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Tile System Details'']]
  
 +
[[Main Page | <i class="fa fa-home fa"></i> Home]]
  
[[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Slate Application'']]
+
{{Tempate:RPM Page Footer with Copyright and Current Date}}
 
 
[[Tile and Slate Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Tile and Slate Construction Details'']]
 
 
 
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Construction Details'']]
 

Latest revision as of 21:07, 7 September 2021



Division D - Construction Details


TS Details:E4.7.2 (Tile - Rake Edge)

Notice to Reader
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority.

The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks
Tile Roofing Details

7.3.2.2.14.jpg

1 WORK INCLUDED

(1) Rake tiles
Rake tiles cover the exposed edge of field tiles at fascia boards. This helps prevent wind driven rain from entering the system and provides an attractive finish. Rake tiles “butt” against the lower edge of the field tile courses then are fastened with two nails into the fascia.

NOTE: See the Standard for additional requirements.


Back to Tile System Details

Home

© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.