Difference between revisions of "Table Drafts 5"
Difference between revisions of "Table Drafts 5"
(One intermediate revision by the same user not shown) | |||
Line 25: | Line 25: | ||
| [[Manufacturers:Carlisle SynTec Systems Canada | Carlisle SynTec Systems Canada]] || style="text-align:center;"| [[Materials:Carlisle Roof Garden Extensive Stormwater Retention System | Carlisle Roof Garden Extensive Stormwater Retention System ]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 140 (5-1/2) || style="text-align:center;"| 140 (5-1/2) || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 101.6 (4) | | [[Manufacturers:Carlisle SynTec Systems Canada | Carlisle SynTec Systems Canada]] || style="text-align:center;"| [[Materials:Carlisle Roof Garden Extensive Stormwater Retention System | Carlisle Roof Garden Extensive Stormwater Retention System ]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 140 (5-1/2) || style="text-align:center;"| 140 (5-1/2) || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 101.6 (4) | ||
|- | |- | ||
− | | [[Manufacturers:Carlisle SynTec Systems Canada | Carlisle SynTec Systems Canada]] || style="text-align:center;"| [[Materials:Carlisle Semi-Intensive Roof Garden System | Carlisle Semi-Intensive Roof Garden System]] || style="text-align:center;"| Semi-Intensive || style="text-align:center;"| PMRA | + | | [[Manufacturers:Carlisle SynTec Systems Canada | Carlisle SynTec Systems Canada]] || style="text-align:center;"| [[Materials:Carlisle Semi-Intensive Roof Garden System | Carlisle Semi-Intensive Roof Garden System]] || style="text-align:center;"| Semi-Intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 158.8 (6-1/4) || style="text-align:center;"| 235 (9-1/4) || style="text-align:center;"| 127 (5) || style="text-align:center;"| 203.2 (8) |
|- | |- | ||
− | | [[Manufacturers:Carlisle SynTec Systems Canada | Carlisle SynTec Systems Canada]] || style="text-align:center;"| [[Materials:Carlisle Intensive Roof Garden System | Carlisle Intensive Roof Garden System]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA | + | | [[Manufacturers:Carlisle SynTec Systems Canada | Carlisle SynTec Systems Canada]] || style="text-align:center;"| [[Materials:Carlisle Intensive Roof Garden System | Carlisle Intensive Roof Garden System]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 235 (9-1/4) || style="text-align:center;"| None Stated || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| None Stated |
|- | |- | ||
| [[Manufacturers:Hydrotech Membrane Corporation | Hydrotech Membrane Corporation]] || style="text-align:center;"| [[Materials:Hydrotech Extensive Garden Roof Assembly | Hydrotech Extensive Garden Roof Assembly]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 203.2 (7) || style="text-align:center;"| 76.2 (3) || style="text-align:center;"| 152.4 (6) | | [[Manufacturers:Hydrotech Membrane Corporation | Hydrotech Membrane Corporation]] || style="text-align:center;"| [[Materials:Hydrotech Extensive Garden Roof Assembly | Hydrotech Extensive Garden Roof Assembly]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 203.2 (7) || style="text-align:center;"| 76.2 (3) || style="text-align:center;"| 152.4 (6) | ||
|- | |- | ||
− | | [[Manufacturers:Hydrotech Membrane Corporation | Hydrotech Membrane Corporation]] || style="text-align:center;"| [[Materials:Hydrotech Semi-intensive Garden Roof Assembly |Hydrotech Semi-intensive Garden Roof Assembly]] || style="text-align:center;"| Semi-Intensive || style="text-align:center;"| PMRA | + | | [[Manufacturers:Hydrotech Membrane Corporation | Hydrotech Membrane Corporation]] || style="text-align:center;"| [[Materials:Hydrotech Semi-intensive Garden Roof Assembly |Hydrotech Semi-intensive Garden Roof Assembly]] || style="text-align:center;"| Semi-Intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 355.6 (14) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| 304.8 (12) |
|- | |- | ||
− | | [[Manufacturers:Hydrotech Membrane Corporation | Hydrotech Membrane Corporation]] || style="text-align:center;"| [[Materials:Hydrotech Intensive Garden Roof Assembly | Hydrotech Intensive Garden Roof Assembly]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA | + | | [[Manufacturers:Hydrotech Membrane Corporation | Hydrotech Membrane Corporation]] || style="text-align:center;"| [[Materials:Hydrotech Intensive Garden Roof Assembly | Hydrotech Intensive Garden Roof Assembly]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 355.6 (14) || style="text-align:center;"| 939.8 (37) || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| 889 (35) |
|- | |- | ||
| [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM LiteN'Less | NLSM LiteN'Less]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 40.7 (1-5/8) || style="text-align:center;"| 64.0 (2-1/2) || style="text-align:center;"| 25.4 (1) || style="text-align:center;"| 25.4 (1) | | [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM LiteN'Less | NLSM LiteN'Less]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 40.7 (1-5/8) || style="text-align:center;"| 64.0 (2-1/2) || style="text-align:center;"| 25.4 (1) || style="text-align:center;"| 25.4 (1) | ||
Line 47: | Line 47: | ||
| [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM StormCap Detain 3° | NLSM StormCap Detain 3°]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 114 (4-1/2) || style="text-align:center;"| 352 (13-7/8) || style="text-align:center;"| 70 (2-3/4) || style="text-align:center;"| 170 (6-11/16) | | [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM StormCap Detain 3° | NLSM StormCap Detain 3°]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 114 (4-1/2) || style="text-align:center;"| 352 (13-7/8) || style="text-align:center;"| 70 (2-3/4) || style="text-align:center;"| 170 (6-11/16) | ||
|- | |- | ||
− | | [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM Eco-Grass | NLSM Eco-Grass]] || style="text-align:center;"| Semi-Intensive || style="text-align:center;"| PMRA | + | | [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM Eco-Grass | NLSM Eco-Grass]] || style="text-align:center;"| Semi-Intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 188 (7-7/16) || style="text-align:center;"| 338 (13-5/16) || style="text-align:center;"| 170 (6-11/16) || style="text-align:center;"| 320 (12-9/16) |
|- | |- | ||
− | | [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM Flora Garden | NLSM Flora Garden]] || style="text-align:center;"| Semi-Intensive || style="text-align:center;"| PMRA | + | | [[Manufacturers:Next Level Stormwater Management | Next Level Stormwater Management]] || style="text-align:center;"| [[Materials:NLSM Flora Garden | NLSM Flora Garden]] || style="text-align:center;"| Semi-Intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 162 (6-3/8) || style="text-align:center;"| 312 (12-5/16) || style="text-align:center;"| 150.4 (6) || style="text-align:center;"| 304.8 (12) |
|- | |- | ||
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SOPRANATURE Extensive-Conventional Vegetated Roof | SOPRANATURE<sup>®</sup> Extensive-Conv. Veg. Roof]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 85.85 (3-3/8) || style="text-align:center;"| 162 (6-3/8) || style="text-align:center;"| 76.2 (3) || style="text-align:center;"| 152.4 (6) | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SOPRANATURE Extensive-Conventional Vegetated Roof | SOPRANATURE<sup>®</sup> Extensive-Conv. Veg. Roof]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 85.85 (3-3/8) || style="text-align:center;"| 162 (6-3/8) || style="text-align:center;"| 76.2 (3) || style="text-align:center;"| 152.4 (6) | ||
Line 59: | Line 59: | ||
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SOPRANATURE Modular-Inverted Vegetated Roof | SOPRANATURE<sup>®</sup> Modular-Inverted Veg. Roof]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 100.5 (3-15/16) || style="text-align:center;"| 100.5 (3-15/16) || style="text-align:center;"| 100 (3-7/8) || style="text-align:center;"| 100 (3-7/8) | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SOPRANATURE Modular-Inverted Vegetated Roof | SOPRANATURE<sup>®</sup> Modular-Inverted Veg. Roof]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 100.5 (3-15/16) || style="text-align:center;"| 100.5 (3-15/16) || style="text-align:center;"| 100 (3-7/8) || style="text-align:center;"| 100 (3-7/8) | ||
|- | |- | ||
− | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SOPRANATURE Semi-Intensive-Inverted (or Urban Agriculture) Vegetated Roof | SOPRANATURE<sup>®</sup> Semi-Intensive-Inverted Veg. Roof]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| PMRA | + | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SOPRANATURE Semi-Intensive-Inverted (or Urban Agriculture) Vegetated Roof | SOPRANATURE<sup>®</sup> Semi-Intensive-Inverted Veg. Roof]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 164.3 (6-6/16) || style="text-align:center;"| 316.7 (12-6/16) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| 304.8 (12) |
|- | |- | ||
− | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SOPRANATURE Intensive-Inverted Vegetated Roof | SOPRANATURE<sup>®</sup> Intensive-Inverted Veg. Roof]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA** || style="text-align:center;"| 361.7 (12-6/16) || style="text-align:center;"| 361.7 (12-6/16) + || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| 304.8 (12) + | + | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SOPRANATURE Semi-Intensive-Conventional (or Urban Agriculture) Vegetated Roof | SOPRANATURE® Semi-Intensive-Conventional (or Urban Agriculture) Vegetated Roof<sup>**</sup>]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| PMRA** || style="text-align:center;"| 164.3 (6-6/16) || style="text-align:center;"| 316.7 (12-6/16) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| 304.8 (12) |
+ | |- | ||
+ | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SOPRANATURE Intensive-Inverted Vegetated Roof | SOPRANATURE<sup>®</sup> Intensive-Inverted Veg. Roof]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 361.7 (12-6/16) || style="text-align:center;"| 361.7 (12-6/16) + || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| 304.8 (12) + | ||
+ | |- | ||
+ | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SOPRANATURE Intensive-Conventional Vegetated Roof | SOPRANATURE® Intensive-Conventional Vegetated Roof<sup>**</sup>]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA** || style="text-align:center;"| 361.7 (12-6/16) || style="text-align:center;"| 361.7 (12-6/16) + || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| 304.8 (12) + | ||
+ | |- | ||
+ | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SKYWATER Ballasted-Inverted Hybrid Roof | SKYWATER<sup>®</sup> Ballasted-Inverted Hybrid Roof]] || style="text-align:center;"| Hybrid || style="text-align:center;"| PMRA || style="text-align:center;"| 107.9 (4-1/4) || style="text-align:center;"| 336.5 (13-1/4) + || style="text-align:center;"| 76.3 (3) || style="text-align:center;"| 304.8 (12) + | ||
|- | |- | ||
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SKYWATER Ballasted-Conventional Hybrid Roof | SKYWATER<sup>®</sup> Ballasted-Conv. Hybrid Roof]] || style="text-align:center;"| Hybrid || style="text-align:center;"| PMRA** || style="text-align:center;"| 107.9 (4-1/4) || style="text-align:center;"| 336.5 (13-1/4) + || style="text-align:center;"| 76.3 (3) || style="text-align:center;"| 304.8 (12) + | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SKYWATER Ballasted-Conventional Hybrid Roof | SKYWATER<sup>®</sup> Ballasted-Conv. Hybrid Roof]] || style="text-align:center;"| Hybrid || style="text-align:center;"| PMRA** || style="text-align:center;"| 107.9 (4-1/4) || style="text-align:center;"| 336.5 (13-1/4) + || style="text-align:center;"| 76.3 (3) || style="text-align:center;"| 304.8 (12) + | ||
− | |||
− | |||
|- | |- | ||
| [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SKYWATER SOPRAFLOW CONTROL-Conventional Hybrid Roof | SKYWATER<sup>®</sup> SOPRAFLOW CONTROL]] || style="text-align:center;"| Hybrid || style="text-align:center;"| PMRA** || style="text-align:center;"| 136.9 (5-3/8) || style="text-align:center;"| 265.2 (14-3/8) || style="text-align:center;"| 76.3 (3) || style="text-align:center;"| 304.8 (12) + | | [[Manufacturers:Soprema Inc. | Soprema Inc.]] || style="text-align:center;"| [[Materials:SKYWATER SOPRAFLOW CONTROL-Conventional Hybrid Roof | SKYWATER<sup>®</sup> SOPRAFLOW CONTROL]] || style="text-align:center;"| Hybrid || style="text-align:center;"| PMRA** || style="text-align:center;"| 136.9 (5-3/8) || style="text-align:center;"| 265.2 (14-3/8) || style="text-align:center;"| 76.3 (3) || style="text-align:center;"| 304.8 (12) + | ||
Line 77: | Line 81: | ||
| [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Sedum Roof XL (Inverted) | ZinCo Sedum Roof XL (Inverted)]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 114.3 (4-1/2) || style="text-align:center;"| 152.4 mm (6) || style="text-align:center;"| 80 (3-1/8) || style="text-align:center;"| 80 (3-1/8) | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Sedum Roof XL (Inverted) | ZinCo Sedum Roof XL (Inverted)]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 114.3 (4-1/2) || style="text-align:center;"| 152.4 mm (6) || style="text-align:center;"| 80 (3-1/8) || style="text-align:center;"| 80 (3-1/8) | ||
|- | |- | ||
− | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Semi-Intensive Perennial Garden Assembly (Inverted) | ZinCo Semi-Intensive Perennial Garden Assembly (Inverted)]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| PMRA** || style="text-align:center;"| 185 (7-1/4) || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| 152.4 (6) | + | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Semi-Intensive Perennial Garden Assembly (Inverted) | ZinCo Semi-Intensive Perennial Garden Assembly (Inverted)]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 185 (7-1/4) || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| 152.4 (6) |
+ | |- | ||
+ | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Semi-Intensive Perennial Garden Assembly | ZinCo Semi-Intensive Perennial Garden Assembly<sup>**</sup>]] || style="text-align:center;"| Semi-intensive || style="text-align:center;"| PMRA** || style="text-align:center;"| 185 (7-1/4) || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 152.4 (6) || style="text-align:center;"| 152.4 (6) | ||
+ | |- | ||
+ | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Roof Garden Assembly (Inverted) | ZinCo Roof Garden Assembly (Inverted)]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 241.3 (9-1/2) || style="text-align:center;"| 260.35 (10-1/4) || style="text-align:center;"| 203.1 (8) || style="text-align:center;"| 203.1 (8) | ||
+ | |- | ||
+ | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Roof Garden Assembly | ZinCo Roof Garden Assembly<sup>**</sup>]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA** || style="text-align:center;"| 241.3 (9-1/2) || style="text-align:center;"| 260.35 (10-1/4) || style="text-align:center;"| 203.1 (8) || style="text-align:center;"| 203.1 (8) | ||
|- | |- | ||
− | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Roof | + | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Blue Roof Assembly (Inverted) | ZinCo Blue Roof Assembly (Inverted)]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA || style="text-align:center;"| 215.9 (8-1/2) || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| 101.6 (10) || style="text-align:center;"| 304.8 (12) |
|- | |- | ||
− | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Blue Roof Assembly | + | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Blue Roof Assembly | ZinCo Blue Roof Assembly<sup>**</sup>]] || style="text-align:center;"| Intensive || style="text-align:center;"| PMRA** || style="text-align:center;"| 215.9 (8-1/2) || style="text-align:center;"| 304.8 (12) || style="text-align:center;"| 101.6 (10) || style="text-align:center;"| 304.8 (12) |
|- | |- | ||
| [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Green Roof & Solar | ZinCo Green Roof & Solar]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 101.6 (4) | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Green Roof & Solar | ZinCo Green Roof & Solar]] || style="text-align:center;"| Extensive || style="text-align:center;"| All || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 101.6 (4) | ||
Line 87: | Line 97: | ||
| [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Green Roof & Solar (Inverted) | ZinCo Green Roof & Solar (Inverted)]] || style="text-align:center;"| Extensive || style="text-align:center;"| PMRA** || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 101.6 (4) | | [[Manufacturers:ZinCo Canada Inc. | ZinCo Canada Inc.]] || style="text-align:center;"| [[Materials:ZinCo Green Roof & Solar (Inverted) | ZinCo Green Roof & Solar (Inverted)]] || style="text-align:center;"| Extensive || style="text-align:center;"| PMRA** || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 203.2 (8) || style="text-align:center;"| 101.6 (4) || style="text-align:center;"| 101.6 (4) | ||
|- | |- | ||
− | {| | + | {| |
::<sup>*</sup> Click on the '''Vegetated Roof Name''' to link to the system page for specified or optional vegetation profiles | ::<sup>*</sup> Click on the '''Vegetated Roof Name''' to link to the system page for specified or optional vegetation profiles | ||
− | ::<sup>**</sup> While ''Semi-intensive'', ''Intensive'', and Hybrid (blue-green) ''vegetated roof systems'' are permitted only on ''protected membrane roofs'' (also called "inverted roof assemblies"; see the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some ''vegetated roof system'' manufacturers offer their systems for ''conventionally insulated roofs'' (these systems are accepted by the RGC and listed | + | ::<sup>**</sup> While ''Semi-intensive'', ''Intensive'', and Hybrid (blue-green) ''vegetated roof systems'' are permitted only on ''protected membrane roofs'' (also called "inverted roof assemblies"; see the [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentence 1.1.3.2.(5)] in the "RGC Standard for Vegetated Roofs"), some ''vegetated roof system'' manufacturers offer their systems for ''conventionally insulated roofs'' (these systems are accepted by the RGC and listed here but are non-conforming to the RGC Standard). Consult the system manufacturer for a re-design of the system for use on a ''protected membrane roof'', or submit a request to the RGC for a written Variance to permit the system on a ''conventionally insulated roof assembly'' following the requirements in [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.6._Variances Article 1.1.3.6.]. |
::<sup>†</sup> ''Vegetated roof systems'' can be divided into three classic '''types''': ''Extensive'', ''Semi-intensive'', and ''Intensive''. Added to this are blue-green roofs, also referred to as "hybrid systems." Refer to the Notes to the [https://rpm.rcabc.org/index.php?title=Notes_to_VRA_Standard Notes to the Standard for Vegetated Roofs] for an expanded treatment on the three principal types. To learn more about RGC requirements for hybrid systems, see [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentences 1.1.3.2.(6) through (8)] in the "RGC Standard for Vegetated Roofs". | ::<sup>†</sup> ''Vegetated roof systems'' can be divided into three classic '''types''': ''Extensive'', ''Semi-intensive'', and ''Intensive''. Added to this are blue-green roofs, also referred to as "hybrid systems." Refer to the Notes to the [https://rpm.rcabc.org/index.php?title=Notes_to_VRA_Standard Notes to the Standard for Vegetated Roofs] for an expanded treatment on the three principal types. To learn more about RGC requirements for hybrid systems, see [https://rpm.rcabc.org/index.php?title=VRA_Standard#1.1.3.2._Permitted_Vegetated_Roof_Systems Sentences 1.1.3.2.(6) through (8)] in the "RGC Standard for Vegetated Roofs". | ||
::<sup>‡</sup> Minimum system and growing media depths may vary. For example, some manufacturers produce retention/detention mats in various thicknesses, to accommodate varying hydrological requirements. This may affect the minimum thickness of a system. Similarly, manufacturers may specify different minimum growing media depths depending on how the system will be used (i.e., deeper media if an intensive system is to be cultivated for rooftop agriculture). Always refer to the '''system page''' for more information. | ::<sup>‡</sup> Minimum system and growing media depths may vary. For example, some manufacturers produce retention/detention mats in various thicknesses, to accommodate varying hydrological requirements. This may affect the minimum thickness of a system. Similarly, manufacturers may specify different minimum growing media depths depending on how the system will be used (i.e., deeper media if an intensive system is to be cultivated for rooftop agriculture). Always refer to the '''system page''' for more information. |
Latest revision as of 15:57, 3 December 2024
Division C - Accepted Materials
Vegetated ("Green") Roof Systems (VRS)
VRS Supplier | VR System Name * | VRS Type † |
Permissible Roof Assembly† |
System Min. Depth mm (in) ‡ |
System Max. Depth mm (in) |
Media Min. Depth mm (in) ‡ |
Media Max. Depth mm (in) |
---|---|---|---|---|---|---|---|
Carlisle SynTec Systems Canada | Carlisle Extensive Roof Garden System | Extensive | All | 101.6 (4) | 127 (5) | 70 (1-1/4) | 127 (5) |
Carlisle SynTec Systems Canada | Carlisle Roof Garden Extensive Stormwater Retention System | Extensive | All | 140 (5-1/2) | 140 (5-1/2) | 101.6 (4) | 101.6 (4) |
Carlisle SynTec Systems Canada | Carlisle Semi-Intensive Roof Garden System | Semi-Intensive | PMRA | 158.8 (6-1/4) | 235 (9-1/4) | 127 (5) | 203.2 (8) |
Carlisle SynTec Systems Canada | Carlisle Intensive Roof Garden System | Intensive | PMRA | 235 (9-1/4) | None Stated | 203.2 (8) | None Stated |
Hydrotech Membrane Corporation | Hydrotech Extensive Garden Roof Assembly | Extensive | All | 101.6 (4) | 203.2 (7) | 76.2 (3) | 152.4 (6) |
Hydrotech Membrane Corporation | Hydrotech Semi-intensive Garden Roof Assembly | Semi-Intensive | PMRA | 203.2 (8) | 355.6 (14) | 152.4 (6) | 304.8 (12) |
Hydrotech Membrane Corporation | Hydrotech Intensive Garden Roof Assembly | Intensive | PMRA | 355.6 (14) | 939.8 (37) | 304.8 (12) | 889 (35) |
Next Level Stormwater Management | NLSM LiteN'Less | Extensive | All | 40.7 (1-5/8) | 64.0 (2-1/2) | 25.4 (1) | 25.4 (1) |
Next Level Stormwater Management | NLSM LiteN'Less II | Extensive | All | 30.7 (1-1/8) | 30.7 (1-1/8) | 20 (13/16) | 20 (13/16) |
Next Level Stormwater Management | NLSM LiteN'Less III | Extensive | All | 45.0 (1-13/16) | 62.0 (2-7/16) | 20 (13/16) | 20 (13/16) |
Next Level Stormwater Management | NLSM TerraEXT | Extensive | All | 113.0 (4-13/16) | 188 (7-13/16) | 95.0 (3-3/4) | 170 (6-11/16) |
Next Level Stormwater Management | NLSM StormCap | Extensive | All | 114 (4-1/2) | 264 (10-3/8) | 70 (2-3/4) | 170 (6-11/16) |
Next Level Stormwater Management | NLSM StormCap Detain 3° | Extensive | All | 114 (4-1/2) | 352 (13-7/8) | 70 (2-3/4) | 170 (6-11/16) |
Next Level Stormwater Management | NLSM Eco-Grass | Semi-Intensive | PMRA | 188 (7-7/16) | 338 (13-5/16) | 170 (6-11/16) | 320 (12-9/16) |
Next Level Stormwater Management | NLSM Flora Garden | Semi-Intensive | PMRA | 162 (6-3/8) | 312 (12-5/16) | 150.4 (6) | 304.8 (12) |
Soprema Inc. | SOPRANATURE® Extensive-Conv. Veg. Roof | Extensive | All | 85.85 (3-3/8) | 162 (6-3/8) | 76.2 (3) | 152.4 (6) |
Soprema Inc. | SOPRANATURE® Extensive-Inverted Veg. Roof | Extensive | All | 88.1 (3-6/16) | 164.3 (6-6/16) | 76.3 (3) | 152.4 (6) |
Soprema Inc. | SOPRANATURE® Modular-Conv. Veg. Roof | Extensive | All | 100.5 (3-15/16) | 100.5 (3-15/16) | 100 (3-7/8) | 100 (3-7/8) |
Soprema Inc. | SOPRANATURE® Modular-Inverted Veg. Roof | Extensive | All | 100.5 (3-15/16) | 100.5 (3-15/16) | 100 (3-7/8) | 100 (3-7/8) |
Soprema Inc. | SOPRANATURE® Semi-Intensive-Inverted Veg. Roof | Semi-intensive | PMRA | 164.3 (6-6/16) | 316.7 (12-6/16) | 152.4 (6) | 304.8 (12) |
Soprema Inc. | SOPRANATURE® Semi-Intensive-Conventional (or Urban Agriculture) Vegetated Roof** | Semi-intensive | PMRA** | 164.3 (6-6/16) | 316.7 (12-6/16) | 152.4 (6) | 304.8 (12) |
Soprema Inc. | SOPRANATURE® Intensive-Inverted Veg. Roof | Intensive | PMRA | 361.7 (12-6/16) | 361.7 (12-6/16) + | 304.8 (12) | 304.8 (12) + |
Soprema Inc. | SOPRANATURE® Intensive-Conventional Vegetated Roof** | Intensive | PMRA** | 361.7 (12-6/16) | 361.7 (12-6/16) + | 304.8 (12) | 304.8 (12) + |
Soprema Inc. | SKYWATER® Ballasted-Inverted Hybrid Roof | Hybrid | PMRA | 107.9 (4-1/4) | 336.5 (13-1/4) + | 76.3 (3) | 304.8 (12) + |
Soprema Inc. | SKYWATER® Ballasted-Conv. Hybrid Roof | Hybrid | PMRA** | 107.9 (4-1/4) | 336.5 (13-1/4) + | 76.3 (3) | 304.8 (12) + |
Soprema Inc. | SKYWATER® SOPRAFLOW CONTROL | Hybrid | PMRA** | 136.9 (5-3/8) | 265.2 (14-3/8) | 76.3 (3) | 304.8 (12) + |
ZinCo Canada Inc. | ZinCo Sedum Roof | Extensive | All | 101.6 (4) | 127 (5) | 80 (3-1/8) | 80 (3-1/8) |
ZinCo Canada Inc. | ZinCo Sedum Roof (Inverted) | Extensive | All | 101.6 (4) | 127 (5) | 80 (3-1/8) | 80 (3-1/8) |
ZinCo Canada Inc. | ZinCo Sedum Roof XL | Extensive | All | 114.3 (4-1/2) | 152.4 mm (6) | 80 (3-1/8) | 80 (3-1/8) |
ZinCo Canada Inc. | ZinCo Sedum Roof XL (Inverted) | Extensive | All | 114.3 (4-1/2) | 152.4 mm (6) | 80 (3-1/8) | 80 (3-1/8) |
ZinCo Canada Inc. | ZinCo Semi-Intensive Perennial Garden Assembly (Inverted) | Semi-intensive | PMRA | 185 (7-1/4) | 203.2 (8) | 152.4 (6) | 152.4 (6) |
ZinCo Canada Inc. | ZinCo Semi-Intensive Perennial Garden Assembly** | Semi-intensive | PMRA** | 185 (7-1/4) | 203.2 (8) | 152.4 (6) | 152.4 (6) |
ZinCo Canada Inc. | ZinCo Roof Garden Assembly (Inverted) | Intensive | PMRA | 241.3 (9-1/2) | 260.35 (10-1/4) | 203.1 (8) | 203.1 (8) |
ZinCo Canada Inc. | ZinCo Roof Garden Assembly** | Intensive | PMRA** | 241.3 (9-1/2) | 260.35 (10-1/4) | 203.1 (8) | 203.1 (8) |
ZinCo Canada Inc. | ZinCo Blue Roof Assembly (Inverted) | Intensive | PMRA | 215.9 (8-1/2) | 304.8 (12) | 101.6 (10) | 304.8 (12) |
ZinCo Canada Inc. | ZinCo Blue Roof Assembly** | Intensive | PMRA** | 215.9 (8-1/2) | 304.8 (12) | 101.6 (10) | 304.8 (12) |
ZinCo Canada Inc. | ZinCo Green Roof & Solar | Extensive | All | 203.2 (8) | 203.2 (8) | 101.6 (4) | 101.6 (4) |
ZinCo Canada Inc. | ZinCo Green Roof & Solar (Inverted) | Extensive | PMRA** | 203.2 (8) | 203.2 (8) | 101.6 (4) | 101.6 (4) |
- * Click on the Vegetated Roof Name to link to the system page for specified or optional vegetation profiles
- ** While Semi-intensive, Intensive, and Hybrid (blue-green) vegetated roof systems are permitted only on protected membrane roofs (also called "inverted roof assemblies"; see the Sentence 1.1.3.2.(5) in the "RGC Standard for Vegetated Roofs"), some vegetated roof system manufacturers offer their systems for conventionally insulated roofs (these systems are accepted by the RGC and listed here but are non-conforming to the RGC Standard). Consult the system manufacturer for a re-design of the system for use on a protected membrane roof, or submit a request to the RGC for a written Variance to permit the system on a conventionally insulated roof assembly following the requirements in Article 1.1.3.6..
- † Vegetated roof systems can be divided into three classic types: Extensive, Semi-intensive, and Intensive. Added to this are blue-green roofs, also referred to as "hybrid systems." Refer to the Notes to the Notes to the Standard for Vegetated Roofs for an expanded treatment on the three principal types. To learn more about RGC requirements for hybrid systems, see Sentences 1.1.3.2.(6) through (8) in the "RGC Standard for Vegetated Roofs".
- ‡ Minimum system and growing media depths may vary. For example, some manufacturers produce retention/detention mats in various thicknesses, to accommodate varying hydrological requirements. This may affect the minimum thickness of a system. Similarly, manufacturers may specify different minimum growing media depths depending on how the system will be used (i.e., deeper media if an intensive system is to be cultivated for rooftop agriculture). Always refer to the system page for more information.