Difference between revisions of "Insulation Joints and Overlays"
Difference between revisions of "Insulation Joints and Overlays"
(→Insulation Joint Tape) |
|||
(24 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | === | + | {{Template:RPM Info}} |
− | < | + | |
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | <div class="col-md-3" style="float:right;" id="tocDiv"> | ||
+ | __TOC__ | ||
+ | </div> <!-- tocDiv --> | ||
+ | |||
+ | <div class="col-md-9" id="mainBodyDiv"> | ||
+ | |||
+ | <big><big>Division E - General Information</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>Insulation Joints and Overlays</big></big></big></big></big> | ||
+ | {| class="wikitable" | style="color: black; background-color: #ffffcc; width: 100%;" | ||
+ | | colspan="2" | '''NOTICE TO READER''': This is an <u>information page only</u>. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in [[Division B | '''Division B''']]. | ||
+ | |} | ||
+ | |||
+ | <big><big><big>General</big></big></big> | ||
+ | |||
+ | Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons: | ||
* to prevent the insulation from affecting the performance of the roof membrane | * to prevent the insulation from affecting the performance of the roof membrane | ||
Line 11: | Line 28: | ||
The roof membrane and / or the method of application can affect the insulation in the following ways: | The roof membrane and / or the method of application can affect the insulation in the following ways: | ||
* the insulation may not be capable of withstanding asphalt application temperatures and may “burn-out” | * the insulation may not be capable of withstanding asphalt application temperatures and may “burn-out” | ||
− | * some | + | * some insulation materials will not accommodate direct torch-applied membranes |
− | * | + | * insulation materials that are too “soft” may result in delamination or damage to the membrane or insulation when exposed to heavy loads or traffic |
* the solvents and adhesives used for flexible membranes may adversely affect the insulation. | * the solvents and adhesives used for flexible membranes may adversely affect the insulation. | ||
− | |||
− | <b>NOTE</b>: All hot asphalt-adhered asphaltic membranes (built-up roofing, modified bitumen, etc.) require an insulation overlay over heat sensitive insulations and heat | + | <b>NOTE</b>: All hot asphalt-adhered asphaltic membranes (built-up roofing, modified bitumen, etc.) require an insulation overlay over heat sensitive insulations and heat resistant foam insulation. '''''RoofStar Guarantee Standards''''' for heat sensitive insulation materials<b> require</b> a two-layer overlay board for a '''RoofStar Roofing Practices Manual''' for a '''''RoofStar 5-Year Roofing Guarantee''''', '''''RoofStar 10-Year Roofing Guarantee''''', or a '''''RoofStar 5-Year Waterproofing Guarantee'''''. The '''''RoofStar Guarantee Program''''' <b>requires</b> the use of a two-layer overlay board over heat sensitive insulation in all cases, and also <b>requires</b> a single-layer overlay board application over heat insensitive insulation for all hot asphalt-adhered membranes. For single-ply, non-asphaltic membrane roofing systems, the membrane manufacturer should be consulted for proprietary options. |
− | < | + | <big><big><big>Insulation Joint Tape</big></big></big> |
− | + | Where the '''''RoofStar Guarantee Standards''''' or the roof system specifications call for | |
− | Where | + | taping fibreboard or insulation joints, consult the list of '''[[Insulation Joint Tape|Accepted Materials: Insulation Joint Tape]]''' section of this Manual. |
− | taping fibreboard or insulation joints, consult the list of '''[[Insulation Joint Tape|Accepted Materials: Insulation Joint Tape]]''' section of this Manual | ||
− | + | <big><big><big>Asphalt and Paraffin-Impregnated / Coated Fibreboard Roof Insulation and Insulation Overlay Board</big></big></big> | |
Under construction | Under construction | ||
− | + | <big><big><big>Proprietary Overlay Boards</big></big></big> | |
Under construction | Under construction | ||
− | + | <hr> | |
+ | |||
+ | <big><big><big>Materials</big></big></big> | ||
+ | |||
+ | To view materials accepted for use in the '''''RoofStar Guarantee Program''''', see the tables under '''[[Roofs_-_Insulation_Overlays|Insulation Overlay Board]]'''. | ||
+ | </div><!-- mainBodyDiv --> | ||
+ | </div><!-- row --> | ||
+ | <div class="col-md-12"> | ||
+ | <hr> | ||
+ | |||
+ | [[Main Page | <i class="fa fa-home fa"></i> Home]] | ||
+ | </div> | ||
− | + | {{Tempate:RPM Page Footer with Copyright and Current Date}} |
Latest revision as of 15:44, 9 September 2021
Contents
Division E - General Information
Insulation Joints and Overlays
NOTICE TO READER: This is an information page only. To read the standards applicable to a particular Waterproofing or Water-shedding System, refer to the actual Standard located in Division B. |
General
Insulation overlays are used to separate the roof membrane from the primary insulation, usually for one of two reasons:
- to prevent the insulation from affecting the performance of the roof membrane
- to prevent the roof membrane and / or the method of application from affecting the insulation
The insulation can affect the performance of the roof membrane in the following ways:
- the insulation may be incompatible with the membrane, resulting in a loss of physical properties
- different coefficients of thermal expansion may result in membrane splits / cracks.
The roof membrane and / or the method of application can affect the insulation in the following ways:
- the insulation may not be capable of withstanding asphalt application temperatures and may “burn-out”
- some insulation materials will not accommodate direct torch-applied membranes
- insulation materials that are too “soft” may result in delamination or damage to the membrane or insulation when exposed to heavy loads or traffic
- the solvents and adhesives used for flexible membranes may adversely affect the insulation.
NOTE: All hot asphalt-adhered asphaltic membranes (built-up roofing, modified bitumen, etc.) require an insulation overlay over heat sensitive insulations and heat resistant foam insulation. RoofStar Guarantee Standards for heat sensitive insulation materials require a two-layer overlay board for a RoofStar Roofing Practices Manual for a RoofStar 5-Year Roofing Guarantee, RoofStar 10-Year Roofing Guarantee, or a RoofStar 5-Year Waterproofing Guarantee. The RoofStar Guarantee Program requires the use of a two-layer overlay board over heat sensitive insulation in all cases, and also requires a single-layer overlay board application over heat insensitive insulation for all hot asphalt-adhered membranes. For single-ply, non-asphaltic membrane roofing systems, the membrane manufacturer should be consulted for proprietary options.
Insulation Joint Tape
Where the RoofStar Guarantee Standards or the roof system specifications call for taping fibreboard or insulation joints, consult the list of Accepted Materials: Insulation Joint Tape section of this Manual.
Asphalt and Paraffin-Impregnated / Coated Fibreboard Roof Insulation and Insulation Overlay Board
Under construction
Proprietary Overlay Boards
Under construction
Materials
To view materials accepted for use in the RoofStar Guarantee Program, see the tables under Insulation Overlay Board.
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.