Difference between revisions of "WP Details:F1.7.1(Wearing Course - Concrete Pavers)"
Difference between revisions of "WP Details:F1.7.1(Wearing Course - Concrete Pavers)"
(→WORK INCLUDED) |
(→WORK INCLUDED) |
||
Line 18: | Line 18: | ||
(2) <b>Membrane Primer or Adhesive:</b> Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications. | (2) <b>Membrane Primer or Adhesive:</b> Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications. | ||
− | (3) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPPROTECTION '''Protection Board/Mat''']: Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with the [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing '''RoofStar Guarantee Standards for Waterproofing'''] | + | (3) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPPROTECTION '''Protection Board/Mat''']: Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with the [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing '''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces'''] |
(4) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPWEARING '''Pedestal''']: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling. | (4) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPWEARING '''Pedestal''']: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling. |
Revision as of 18:23, 12 October 2016
RoofStar Guarantee Standards are blue-linked |
1 WORK INCLUDED
(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per the RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces and Membrane Manufacturer's installation specifications.
(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.
(3) Protection Board/Mat: Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with the RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces
(4) Pedestal: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling.
(7) Pavers: Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24").
2 WORK BY OTHERS
(A) Acceptable Deck: Concrete slab depicted.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
Back to Waterproofing Application