WORK INCLUDED

(1) Architectural Metal Roof Panel
(2) Water Tight Back Up Storm Collar
Installed where practical.
(3) Seal Between Pipe And Flashing
Continuous tooled bead of accepted caulking.
(4) Stainless Steel Drawband
(5) Preformed Penetration Collar
(6) High-domed Gasketed Cladding-type Screws
Flange fastened to manufacturer's specifications.
(7) Flange
Set in two continuous beads of accepted caulking.
(8) Separation Layer (Drainage Mat)
Required for slopes less than 1:3; recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(9) Underlayment
The type of underlay required is determined by roof slope.