=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMPANEL |'''Architectural Metal Roof Panel''']]
+
;(1) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMPANEL |'''Architectural Metal Roof Panel''']]
 
;(2) '''Water Tight Back Up Storm Collar''': Installed where practical.
 
;(2) '''Water Tight Back Up Storm Collar''': Installed where practical.
 
;(3) '''Seal Between Pipe And Flashing''': Continuous tooled bead of accepted caulking.  
 
;(3) '''Seal Between Pipe And Flashing''': Continuous tooled bead of accepted caulking.  
 
;(4) '''Stainless Steel Drawband'''  
 
;(4) '''Stainless Steel Drawband'''  
 
;(5) '''Preformed Penetration Collar'''
 
;(5) '''Preformed Penetration Collar'''
;(6) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMCLADSCREW |'''High-domed Gasketed Cladding-type Screws''']]: Flange fastened to manufacturer's specifications.  
+
;(6) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMCLADSCREW |'''High-domed Gasketed Cladding-type Screws''']]: Flange fastened to manufacturer's specifications.  
 
;(7) '''Flange''':  Set in two continuous beads of accepted caulking.  
 
;(7) '''Flange''':  Set in two continuous beads of accepted caulking.  
;(8) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMSLIP|'''Separation Layer (Drainage Mat)''']]: Required for slopes less than 1:3; recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
+
;(8) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMSLIP|'''Separation Layer (Drainage Mat)''']]: Required for slopes less than 1:3; recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
;(9) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope.  
+
;(9) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope.  
  
 
<hr>
 
<hr>
Line 38: Line 38:
 
<hr>
 
<hr>
  
 
+
[[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems|<i class="fa fa-chevron-circle-right fa" ></i> RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems]]
[[RoofStar Guarantee Standards for ASM Roof Assemblies|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for ASM Roof Assemblies]]
 
  
 
[[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']]
 
[[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']]
 
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
 

Revision as of 15:43, 5 October 2020

RoofStar Guarantee Standards are blue-linked
ASM Details

ASM 11.1.1.jpg

Click below for a printable version of this page.
ASM 11.1.1 Thumb for PDF.jpg

WORK INCLUDED

(1) Architectural Metal Roof Panel
(2) Water Tight Back Up Storm Collar
Installed where practical.
(3) Seal Between Pipe And Flashing
Continuous tooled bead of accepted caulking.
(4) Stainless Steel Drawband
(5) Preformed Penetration Collar
(6) High-domed Gasketed Cladding-type Screws
Flange fastened to manufacturer's specifications.
(7) Flange
Set in two continuous beads of accepted caulking.
(8) Separation Layer (Drainage Mat)
Required for slopes less than 1:3; recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(9) Underlayment
The type of underlay required is determined by roof slope.

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.


RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems