Difference between revisions of "Asphalt Shingles - Application (Low Slopes)"

Jump to: navigation, search

Difference between revisions of "Asphalt Shingles - Application (Low Slopes)"

Line 38: Line 38:
 
[[RoofStar Guarantee Standards for Asphalt Shingle Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Asphalt Shingle Systems]]
 
[[RoofStar Guarantee Standards for Asphalt Shingle Systems|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for Asphalt Shingle Systems]]
  
[[Asphalt Shingles Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
+
[[Asphalt Shingle Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Asphalt Shingles Construction Details'']]
  
 
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]
 
[[Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]

Revision as of 14:46, 18 October 2019

RoofStar Guarantee Standards are blue-linked
Asphalt Shingle Details

Applicable to slopes 1:6 (2" in 12") and greater.

7.1.4.1.1.jpg

1 WORK INCLUDED

(1) Underlayment & Eave Protection
One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 150 mm (6") minimum on ends. Also refer to the Accepted Materials section of this Manual.
(2) Edge Metal Flashing
Optional (cf. 2.2.9 Wood Deck Overlay Sheathing (Non-Structural) for specific requirements), installed to manufacturer's printed instructions.
(3) Starter Course
Consists of same type shingles used for roof, applied tabs facing up the slope.
(4) Strip or Standard Shingles
Applied as recommended by manufacturer. Laminated shingles are not acceptable for this application.
(5) Compatible Mastic
Heavy bead of compatible asphaltic mastic at rakes (gables) and valleys.
(6) Protrusions
Curbs and skylights must be flashed with underlayment so as to shed water, with minimum 125mm (5") up vertical surfaces and 150 mm (6") lapping onto field surfaces. Vent stack underlayment flashing should fit tight to the vent pipe and be sealed with compatible mastic. For fire-rated stacks or hot pipe protrusions, strip in secondary metal deck flashing before installing rated stack / pipe flashing.
(7) Nailing
Note manufacturer's recommended nailing pattern. Placement varies with manufacturer.