Difference between revisions of "EPDM Roof System Details"
Difference between revisions of "EPDM Roof System Details"
Line 22: | Line 22: | ||
<hr> | <hr> | ||
<big>1 GENERAL</big> | <big>1 GENERAL</big> | ||
− | :[[EPDM | + | :[[EPDM 1.1.1 Conventionally Insulated System (generic) | EPDM 1.1.1 Conventionally Insulated System (generic)]] |
− | :[[EPDM | + | :[[EPDM 1.1.2 Protected Membrane Roof Assembly (generic) | EPDM 1.1.2 Protected Membrane Roof Assembly (generic)]] |
− | :[[EPDM | + | :[[EPDM 1.1.3 Fully Adhered System (generic) | EPDM 1.1.3 Fully Adhered System (generic)]] |
<big>2 SUPPORTING STRUCTURES: Decks and Walls</big> | <big>2 SUPPORTING STRUCTURES: Decks and Walls</big> |
Revision as of 19:21, 13 November 2019
Editor's note |
---|
This page is currently under revision, as the details are renumbered and new details and printable detail pages are added. Continue to watch for further updates to the this page and the displayed links. |
- The drawings contained within this section are intended to represent a variety of thermoset membrane roof system applications while remaining generic with regards to manufacturers’ specific application specifications. They do not represent all possible manufacturer application roof system designs. Consult manufacturers’ specifications and RoofStar Guarantee Standards to develop a system acceptable to both the manufacturer and the RoofStar Guarantee Program.
- For further information about thermoset membrane (EPDM) system designs and requirements, see EPDM (Thermoset) Membrane Systems.
NOTE: 'PDF' shown after a file name below indicates a downloadable print sheet is available for Construction Details. Click on the detail link and look for the icon.
1 GENERAL
- EPDM 1.1.1 Conventionally Insulated System (generic)
- EPDM 1.1.2 Protected Membrane Roof Assembly (generic)
- EPDM 1.1.3 Fully Adhered System (generic)
2 SUPPORTING STRUCTURES: Decks and Walls
3 SECURING the ROOF ASSEMBLY
4 MATERIALS
5 DECK and WALL OVERLAYS
6 AIR and VAPOUR CONTROLS
7 INSULATION
8 INSULATION OVERLAYS
9 FIELD MEMBRANE
10 PERIMETERS and WALLS
- D2.7.5-1 Roof-Wall Transitions (Expansion Joint)(Under Construction)
- D2.7.5-2 Roof-Wall Transitions (Divider/Joint)(Under Construction)
- D2.7.5-3 Roof-Wall Transitions (Fire Separation Joint)(Under Construction)
- D2.7.5-4 Roof-Wall Transitions (Fire Separation Wall)(Under Construction)
- D2.7.2-1 Parapets & Copings (High - Wall Supported)(Under Construction)
- D2.7.2-2 Parapets & Copings (Parapet - Wall Transition)(Under Construction)
- D2.7.3-1 Edges & Fascia (Cant Edge)(Under Construction)
- D2.7.3-2 Edges & Fascia (Gravel Stop)(Under Construction)
- D2.7.4-1 Counter-flashings & Reglets (Deck - Wall Supported)(Under Construction)
- D2.7.4-2 Counter-flashings & Reglets (Deck - Unsupported by Wall)(Under Construction)
- D2.7.4-3 Counter-flashings & Reglets (Stucco Wall: Re-roofing)(Under Construction)
- D2.7.4-4 Counter-flashings & Reglets (Stucco Wall: New)(Under Construction)
- D2.7.4-5 Counter-flashings & Reglets (Double Surface Reglet)(Under Construction)
- D2.7.4-6 Counter-flashings & Reglets (Low Door Sill)(Under Construction)
- D2.7.4-7 Counter-flashings & Reglets (Window Curb)(Under Construction)
11 DRAINS and PENETRATIONS
- D2.7.6-1 Curbs & Sleepers (Equipment Sleeper)(Under Construction)
- D2.7.6-2 Curbs & Sleepers (Multiple Roof Penetrations)(Under Construction)
- D2.7.6-3 Curbs & Sleepers (Basic Curb)
- D2.7.6-4 Curbs & Sleepers (Mechanical Opening)
- D2.7.7-1 Strip-in Flashings (Metal Plumbing)(Under Construction)
- D2.7.7-2 Strip-in Flashings (Two-part Cable)
- D2.7.7-3 Strip-in Flashings (Pourable Sealer Pocket)(Under Construction)
- D2.7.8-1 Water & Drainage (Cast Iron Drain)(Under Construction)
- D2.7.8-2 Water & Drainage (Spun Copper Drain)(Under Construction)
- D2.7.8-3 Water & Drainage (Clamping Spun Copper Drain)
- D2.7.8-4 Water & Drainage (Open Wall Scupper)(Under Construction)
- D2.7.8-5 Water & Drainage (Through-wall Scupper)(Under Construction)
- D2.7.9-1 Miscellaneous Penetrations (Roof Anchor)(Under Construction)
- D2.7.9-2 Miscellaneous Penetrations (Wall Anchor - Conventional Roof Assy)(Under Construction)
- D2.7.9-3 Miscellaneous Penetrations (Wall Anchor - Protected Roof Assy)(Under Construction)
12 PROTECTED MEMBRANES and OTHER DETAILS
13 METAL FLASHINGS
14 THE ROOF as a PLATFORM