− | { | + | {{Template:RPM Info}} |
− | |||
− | |||
− | |||
− | |||
+ | {{DISPLAYTITLE:<span style="position: absolute; clip: rect(1px 1px 1px 1px); clip: rect(1px, 1px, 1px, 1px);">{{FULLPAGENAME}}</span>}} | ||
+ | __NOTOC__ | ||
+ | |||
+ | <big><big>Division D - Construction Details</big></big> | ||
+ | <hr> | ||
+ | <big><big><big><big><big>SBS | Parapet (Typical) ([[SBS_Roof_Systems_Standard#10.3.4.1._Parapets | Article 10.3.4.1.]])</big></big></big></big></big> | ||
+ | {{Template:Construction Details Header}} | ||
<div class="panel panel-success"> | <div class="panel panel-success"> | ||
− | <div class="panel-heading"><big>''' | + | <div class="panel-heading"><big>'''SBS Details'''</big></div> |
<div class="panel-body"> | <div class="panel-body"> | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
<div style="text-align:center; vertical-align:center"> | <div style="text-align:center; vertical-align:center"> | ||
− | [[File: | + | [[File:10.3.1.1.jpg|class=img-responsive | link=http://rpm.rcabc.org/images/d/dd/10.3.1.1.jpg]] |
</div> | </div> | ||
− | ::Click below for a printable version of this page | + | ::Click below for a printable version of this page. |
<div style="width:150px; text-align: left;"> | <div style="width:150px; text-align: left;"> | ||
− | :[[File:Pdf.png|100 px|link=|'''Print Sheet''']] | + | :[[File:Pdf.png|100 px|link=http://rpm.rcabc.org/images/8/83/D1.7.2-1_Print_Sheet.pdf|'''Print Sheet''']] |
</div> | </div> | ||
</div><!-- COL-MD-6 --> | </div><!-- COL-MD-6 --> | ||
Line 22: | Line 25: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | |||
− | |||
− | |||
− | |||
− | :''' | + | ;(1) [[SBS Roof Systems Standard#PART_2|'''Supporting Deck Overlay''']]: |
− | + | :If required by design authority. | |
− | + | ;(2) [[SBS Roof Systems Standard#PART_6|'''Air or Vapour Control Layers''']]: | |
+ | :If required by design authority. | ||
+ | ;(3) [[SBS Roof Systems Standard#PART_7|'''Insulation''']]: | ||
+ | :See list of '''[[Section:C. Accepted Materials|Accepted Materials]]'''. | ||
+ | ;(4) [[SBS Roof Systems Standard#PART_8|'''Insulation Overlay''']]: | ||
+ | :As required. | ||
+ | ;(5) [[SBS Roof Systems Standard#PART_9|'''Primary Membrane and Membrane Protection''']]: | ||
+ | ;(6) [[SBS Roof Systems Standard#PART_10|'''Membrane Flashing''']]: | ||
+ | :Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge. | ||
+ | ;(7) [[SBS Roof Systems Standard#PART_13|'''Metal Base Flashing''']]: | ||
+ | :Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats. | ||
+ | ;(8) [[SBS Roof Systems Standard#PART_13|'''Metal Cap Flashing''']]: | ||
+ | :Flashings 1 and 2 may be one piece. Fasten with continuous concealed clip-type fasteners <b>or</b> cladding screws evenly spaced between seams. | ||
<hr> | <hr> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[ | + | |
+ | ;(A) [[SBS Roof Systems Standard#PART_2|'''Acceptable Supporting Steel Deck Structure''']] | ||
+ | ;(B) [[SBS Roof Systems Standard#PART_6|'''Air/Vapour Seal''']] | ||
+ | ;(C) [[SBS Roof Systems Standard#PART_2|'''Acceptable Wall Surface''']] | ||
+ | ;(D) '''Wood Blocking''' | ||
+ | ;(E) [[SBS Roof Systems Standard#PART_10|'''Sloped Wood Blocking''']] | ||
+ | :Required over 100 mm (4") parapet width. | ||
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> | ||
</div><!-- PANEL --> | </div><!-- PANEL --> | ||
+ | '''NOTE''': See the [[SBS Roof Systems Standard | '''Standard''']] for additional requirements. | ||
− | + | <hr> | |
− | < | + | [[SBS Roof System Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''"SBS" Roof System Details'']] |
− | [[ | + | [[Main Page | <i class="fa fa-home fa"></i> Home]] |
− | + | {{Tempate:RPM Page Footer with Copyright and Current Date}} |
Revision as of 15:50, 27 October 2022
Division D - Construction Details
SBS | Parapet (Typical) ( Article 10.3.4.1.)
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive, and are not necessarily drawn to scale. They are intended to support the related Standard (Ref. Division A, Article 2.2.1.2.).
The reader may link to the related Article in the detail title, or link to the Standard as it relates to a specific element in the detail. All hyperlinks are displayed blue text. |
SBS Details
1 WORK INCLUDED
- (1) Supporting Deck Overlay
- If required by design authority.
- (2) Air or Vapour Control Layers
- If required by design authority.
- (3) Insulation
- See list of Accepted Materials.
- (4) Insulation Overlay
- As required.
- (5) Primary Membrane and Membrane Protection
- (6) Membrane Flashing
- Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge.
- (7) Metal Base Flashing
- Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats.
- (8) Metal Cap Flashing
- Flashings 1 and 2 may be one piece. Fasten with continuous concealed clip-type fasteners or cladding screws evenly spaced between seams.
2 RELATED WORK BY OTHERS
- (A) Acceptable Supporting Steel Deck Structure
- (B) Air/Vapour Seal
- (C) Acceptable Wall Surface
- (D) Wood Blocking
- (E) Sloped Wood Blocking
- Required over 100 mm (4") parapet width.
NOTE: See the Standard for additional requirements.