Difference between revisions of "Table Drafts 5"
Difference between revisions of "Table Drafts 5"
(Created page with "__NOTOC__ ===Part 9: EPDM Table (Combined 5, 10, 15) REV=== {| class="wikitable mw-datatable" style="margin-left: 10pt; margin-right: auto;border-color:#E7E9E9;ve...") |
(→Part 9: 2-ply Model (Combined 5, 10, 15)) |
||
Line 207: | Line 207: | ||
| rowspan="1" style="text-align:center;background-color:#E9967A" | 5/10 || colspan="6" rowspan="1" style="text-align:center;" | 6.00 || rowspan="1" style="text-align:center;" | 6.00 || rowspan="1" style="text-align:center;" | N/A || rowspan="1" style="text-align:center;" | 6.00 || rowspan="1" style="text-align:center;width=200px;" | N/A | | rowspan="1" style="text-align:center;background-color:#E9967A" | 5/10 || colspan="6" rowspan="1" style="text-align:center;" | 6.00 || rowspan="1" style="text-align:center;" | 6.00 || rowspan="1" style="text-align:center;" | N/A || rowspan="1" style="text-align:center;" | 6.00 || rowspan="1" style="text-align:center;width=200px;" | N/A | ||
|- | |- | ||
− | | rowspan="1" style="text-align:center;background-color:#FA8072" | 15 || colspan="6" rowspan="1" style="text-align:center;" | | + | | rowspan="1" style="text-align:center;background-color:#FA8072" | 15 || colspan="6" rowspan="1" style="text-align:center;" | 6.50 || rowspan="1" style="text-align:center;" | 6.50 || rowspan="1" style="text-align:center;" | N/A || rowspan="1" style="text-align:center;" | 6.50 || rowspan="1" style="text-align:center;width=200px;" | N/A |
|- | |- | ||
| colspan="14" style="border:none;background-color:#E7E9E9;" | | | colspan="14" style="border:none;background-color:#E7E9E9;" | |
Revision as of 19:19, 12 January 2021
1 Part 9: EPDM Table (Combined 5, 10, 15) REV
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | |||||||
Mechanically Fastened; Induction Welded* |
Adhered | Adhesive- applied; Self- adhered |
Loose-laid | Adhered | Adhered | |||||
Self- adhered |
Hot- mopped |
Adhesive- applied | ||||||||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
EPDM (reinforced) | ||||||||||
5 | 1.524 (60) | 1.524 (60) | 1.143 (45) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | X | ||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | X | ||
15 | 2.286 (90) | X | N/A | N/A | 1.524 (60) | X | N/A | X | ||
EPDM (unreinforced) | ||||||||||
5 | X | 1.524 (60) | 1.143 (45) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | X | ||
10 | X | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | X | ||
15 | X | X | 2.286 (90) | 2.286 (90) | 2.286 (90) | X | 2.286 (90) | X |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
2 Part 9: TPO Table (Combined 5, 10, 15) REV
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | |||||||
Mechanically Fastened; Induction Welded* |
Adhered | Adhesive- applied; Self- adhered |
Loose-laid | Adhered | Adhered | |||||
Self- adhered |
Hot- mopped |
Adhesive- applied | ||||||||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
TPO | ||||||||||
5 | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | 1.524 (60) | 1.143 (45) | 1.143 (45) | X | ||
10 | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | X | ||
15 | 2.032 (80) | 2.032 (80) | 2.032 (80) | 2.032 (80) | 2.032 (80) | X | 2.032 (80) | X |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
3 Part 9: PVC Table (Combined 5, 10, 15) REV
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
Ballasted | PMR Systems | |||||||
Mechanically Fastened; Induction Welded* |
Adhered | Adhesive- applied; Self- adhered |
Loose-laid | Adhered | Adhered | |||||
Self- adhered |
Hot- mopped |
Adhesive- applied | ||||||||
Type, Reinforcement, Grade | Guarantee Term | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | mm (mils) | |
PVC | ||||||||||
5 | 1.270 (50) | X | 1.270 (50) | 1.270 (50) | 1.524 (60) | 1.270 (50) | 1.270 (50) | 1.524 (60) | ||
10 | 1.524 (60) | X | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | 1.524 (60) | ||
15 | 2.032 (80) | X | 2.032 (80) | 2.032 (80) | 2.032 (80) | X | 2.032 (80) | X |
- *Induction welding subject to the securement requirements in the applicable membrane Standard, Part 3.
4 Part 9: 2-ply Model (Combined 5, 10, 15)
Exposed Roof Systems | Protected Roof Systems | Grade-level Water- proofing | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Conventionally Insulated / Uninsulated Systems | Built-in Gutters |
PMR Systems | |||||||||||
Mechanic- ally fastened |
Heat- welded |
Adhered | Heat- welded; Adhesive- applied; Self- adhered
|
Heat- welded; Adhered |
Puncture Resistance | Heat- welded; Adhered |
Puncture Resistance | ||||||
Self- adhered |
Hot- mopped |
Adhesive- applied | |||||||||||
Type, Reinforcement, Grade | Guarantee Term | mm | mm | mm | mm | mm | mm | mm | (N) | mm | (N) | ||
Minimum Combined 2-ply Thickness | |||||||||||||
5/10 | 6.00 | 6.00 | N/A | 6.00 | N/A | ||||||||
15 | 6.50 | 6.50 | N/A | 6.50 | N/A | ||||||||
Base (Fibreglass) - Gr. 3 | |||||||||||||
5/10 | 2.30 | 2.30 | 2.30 | 2.20 | 2.20 | X | X | X | X | X | |||
15 | X | 2.50 | 2.50 | 2.50 | 2.50 | X | X | X | X | X | |||
Base (Composite fibreglass) - Gr. 3 | |||||||||||||
5/10 | 2.30 | 2.30 | 2.30 | 2.20 | 2.20 | 2.50 | 2.20 | X | 2.20 | X | |||
15 | X | 2.50 | 2.50 | 2.50 | 2.50 | 2.90 | 2.50 | X | 2.50 | X | |||
Base (Polyester) - Gr. 3 | |||||||||||||
5/10 | 2.50 | 2.50 | 2.50 | 2.20 | 2.20 | 2.50 | 2.20 | X | 2.20 | X | |||
15 | X | 2.50 | 2.50 | 2.50 | 2.50 | 2.90 | 2.50 | X | 2.50 | X | |||
Base (Composite) - Gr. 3 | |||||||||||||
5/10 | 2.30 | 2.30 | 2.30 | 2.20 | 2.20 | 2.50 | 2.20 | X | 2.20 | X | |||
15 | X | 2.50 | 2.50 | 2.50 | 2.50 | 2.90 | 2.50 | X | 2.50 | X | |||
Factory Laminated Base (panel) | |||||||||||||
5/10 | 2.20 | X | 2.20 | N/A | X | N/A | |||||||
15 | 2.20 | X | 2.20 | N/A | X | N/A | |||||||
Film Cap (Fibreglass) - Gr. 2 | |||||||||||||
5/10 | X | 4.00 | 3.30 | 3.30 | 3.30 | X | X | X | X | X | |||
15 | X | X | X | X | X | X | X | X | X | X | |||
Film Cap (Polyester) - Gr. 2 | |||||||||||||
5/10 | X | 4.00 | 3.50 | 3.50 | 3.50 | 3.00 | 3.00 | 400 | 3.00 | 400 | |||
15 | X | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 3.00 | 400 | 3.50 | 400 | |||
Film Cap (Composite) - Gr. 2 | |||||||||||||
5/10 | X | 4.00 | 3.30 | 3.30 | 3.30 | 3.00 | 3.00 | 400 | 3.00 | 400 | |||
15 | X | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 3.00 | 400 | 3.50 | 400 | |||
Granule Cap (Fibreglass) - Gr. 1 | |||||||||||||
5/10 | X | 4.00 | 3.30 | 3.30 | 3.30 | X | X | X | X | X | |||
15 | X | 4.00 | 4.00 | 4.00 | 4.00 | X | X | X | X | X | |||
Granule Cap (Polyester) - Gr. 1 | |||||||||||||
5/10 | X | 4.00 | 3.50 | 3.50 | 3.50 | 3.50 | 3.00 | 400 | 3.00 | 400 | |||
15 | X | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 3.00 | 400 | 3.50 | 400 | |||
Granule Cap (Composite) - Gr. 1 | |||||||||||||
5/10 | X | 3.30 | 4.00 | 3.30 | 3.30 | 3.50 | 3.00 | 400 | 3.00 | 400 | |||
15 | X | 4.00 | 4.00 | 4.00 | 4.00 | 4.00 | 3.00 | 400 | 3.50 | 400 |