Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"
Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"
Line 11: | Line 11: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
<div style="text-align:center; vertical-align:center"> | <div style="text-align:center; vertical-align:center"> | ||
− | [[File:9.6.2.jpg|class=img-responsive]] | + | [[File:9.6.2.jpg| link=http://rpm.rcabc.org/images/5/57/9.6.2.jpg | class=img-responsive]] |
</div> | </div> | ||
</div><!-- COL-MD-6 --> | </div><!-- COL-MD-6 --> |
Revision as of 21:26, 31 August 2021
Notice to Reader | |
Images used in a Construction Detail are representative and not prescriptive. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the requirements of the Standard they represent. Unless otherwise required by the Standard, dimensions, the selection of materials and their application remains the responsibility of the Design Authority. The full text of the referenced requirements in the Standard may be read by using the blue hyperlinks |
Waterproofing Details for Plazas, Promenades and Terraces
1 WORK INCLUDED
- (1) Primary Waterproofing Membrane
- Fully adhered to acceptable substrates (concrete slab shown), installed as per the Standard and the Membrane Manufacturer's installation specifications.
- (2) Membrane Primer or Adhesive
- Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
- (3) Protection Board/Mat
- Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RoofStar Guarantee Standards.
- (4) Drainage Medium
- Proprietary (purpose-made) geocomposite drainage boards with synthetic water permeable fabric required to contain sand and gravel beds for unit masonry (pavers, bricks, and stone).
2 WORK BY OTHERS
- (A) Acceptable Deck
- Concrete slab depicted.
- (B) Unit Masonry Wearing Coarse
- Concrete brick, pavers, stone on sand and gravel or moror beds designed to support predicted live loads.
- (C) Conductive Tape
- Moisture Survey System (tape grid) mandatory and compliant with RoofStar Guarantee Standards. For RoofStar-accepted Moisture Survey Tape Systems, refer to MEMBRANE MOISTURE SURVEYS & MONITORING SENSOR GRIDS.
NOTE: See the Standard for additional requirements.
Back to Grade-level Waterproofing Construction Details
© RCABC 2024
RoofStarTM is a registered Trademark of the RCABC.
No reproduction of this material, in whole or in part, is lawful without the expressed permission of the RCABC Guarantee Corp.