Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"

Jump to: navigation, search

Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"

(Created page with "<hr> File:9.6.2.jpg ;WORK INCLUDED (1)<b>Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed as per <i>RGC Guaran...")
 
Line 2: Line 2:
 
[[File:9.6.2.jpg]]
 
[[File:9.6.2.jpg]]
  
;WORK INCLUDED
+
==== WORK INCLUDED ====
  
 
(1)<b>Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed as per <i>RGC Guarantee Standards E </i>and Membrane
 
(1)<b>Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed as per <i>RGC Guarantee Standards E </i>and Membrane
Line 13: Line 13:
 
(4) <b>Drainage Medium</b>: Proprietary (purpose-made) geocomposite drainage boards with synthetic water permeable fabric required to contain sand and gravel beds for unit masonry (pavers, bricks, and stone).
 
(4) <b>Drainage Medium</b>: Proprietary (purpose-made) geocomposite drainage boards with synthetic water permeable fabric required to contain sand and gravel beds for unit masonry (pavers, bricks, and stone).
  
;WORK BY OTHERS
+
 
 +
==== WORK BY OTHERS ====
  
 
(A)<b> Acceptable Deck</b>: Concrete slab depicted.
 
(A)<b> Acceptable Deck</b>: Concrete slab depicted.
Line 23: Line 24:
 
;NOTE: Refer to RGC Guarantee Standards E for additional requirements.
 
;NOTE: Refer to RGC Guarantee Standards E for additional requirements.
  
 +
<hr>
  
<hr>
 
  
  

Revision as of 17:24, 23 December 2015


9.6.2.jpg

1 WORK INCLUDED

(1)Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per RGC Guarantee Standards E and Membrane Manufacturer's installation specifications.

(2)Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.

(3)Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards E.

(4) Drainage Medium: Proprietary (purpose-made) geocomposite drainage boards with synthetic water permeable fabric required to contain sand and gravel beds for unit masonry (pavers, bricks, and stone).


2 WORK BY OTHERS

(A) Acceptable Deck: Concrete slab depicted.

(B) Unit Masonry Wearing Coarse: Concrete brick, pavers, stone on sand and gravel or moror beds designed to support predicted live loads.

(C) Conductive Tape: Moisture Survey System (tape grid) mandatory and compliant with RGC Guarantee Standards E. For RGC accepted Moisture Survey Tape System s - refer to Section 2.2.

NOTE
Refer to RGC Guarantee Standards E for additional requirements.


Back to Waterproofing

Back to Waterproofing Construction Details

Back to Construction Details