Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"
Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"
Line 1: | Line 1: | ||
− | < | + | <div class="panel panel-success"> |
− | [[File:9.6.2.jpg]] | + | <div class="panel-heading"><big>'''Waterproofing Details for Plazas, Promenades and Terraces'''</big></div> |
− | + | <div class="panel-body"> | |
+ | <div class="col-md-6"> | ||
+ | <div style="text-align:center; vertical-align:center"> | ||
+ | [[File:9.6.2.jpg|class=img-responsive]] | ||
+ | </div> | ||
+ | </div><!-- COL-MD-6 --> | ||
+ | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
Line 23: | Line 29: | ||
(C) <b>Conductive Tape: </b>Moisture Survey System (tape grid) <b>mandatory</b> and compliant with RGC Guarantee Standards <b>E.</b> For RGC accepted Moisture Survey Tape System s - refer to Section 2.2. | (C) <b>Conductive Tape: </b>Moisture Survey System (tape grid) <b>mandatory</b> and compliant with RGC Guarantee Standards <b>E.</b> For RGC accepted Moisture Survey Tape System s - refer to Section 2.2. | ||
− | + | </div><!-- COL-6-MD --> | |
+ | </div><!-- PANEL BODY --> | ||
+ | </div><!-- PANEL --> | ||
+ | |||
+ | '''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements. | ||
<hr> | <hr> | ||
Line 29: | Line 39: | ||
− | |||
− | [[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[Section:F. Application: Waterproofing Plazas, Promenades and Terraces|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Application'']] |
+ | [[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Construction Details'']] | ||
− | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']] |
Revision as of 21:31, 19 August 2016
1 WORK INCLUDED
(1)Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per RGC Guarantee Standards E and Membrane Manufacturer's installation specifications.
(2)Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.
(3)Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards E.
(4) Drainage Medium: Proprietary (purpose-made) geocomposite drainage boards with synthetic water permeable fabric required to contain sand and gravel beds for unit masonry (pavers, bricks, and stone).
2 WORK BY OTHERS
(A) Acceptable Deck: Concrete slab depicted.
(B) Unit Masonry Wearing Coarse: Concrete brick, pavers, stone on sand and gravel or moror beds designed to support predicted live loads.
(C) Conductive Tape: Moisture Survey System (tape grid) mandatory and compliant with RGC Guarantee Standards E. For RGC accepted Moisture Survey Tape System s - refer to Section 2.2.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
Back to Waterproofing Application
Back to Waterproofing Construction Details