Difference between revisions of "WP Details:F1.7.10 (Walls - Double Surface Reglet Flashing)"
Difference between revisions of "WP Details:F1.7.10 (Walls - Double Surface Reglet Flashing)"
Line 1: | Line 1: | ||
− | < | + | <div class="panel panel-success"> |
− | [[File:9.6.10.jpg]] | + | <div class="panel-heading"><big>'''Waterproofing Details for Plazas, Promenades and Terraces'''</big></div> |
− | + | <div class="panel-body"> | |
+ | <div class="col-md-6"> | ||
+ | <div style="text-align:center; vertical-align:center"> | ||
+ | [[File:9.6.10.jpg|class=img-responsive]] | ||
+ | </div> | ||
+ | </div><!-- COL-MD-6 --> | ||
+ | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | (1)<b>Primary Waterproofing Membrane: </b>Fully adhered to acceptable substrates (concrete slab depicted), installed as per <i>RGC Guarantee Standards E </i>and Membrane Manufacturer's installation specifications. | + | (1) <b>Primary Waterproofing Membrane: </b>Fully adhered to acceptable substrates (concrete slab depicted), installed as per <i>RGC Guarantee Standards E </i>and Membrane Manufacturer's installation specifications. |
− | (2)<b> Membrane Flashing: </b>Carried up wall minimum 200 mm (8") above deck surface and minimum 100 mm (4") above top of finished permeable wearing course or overburden. | + | (2) <b> Membrane Flashing: </b>Carried up wall minimum 200 mm (8") above deck surface and minimum 100 mm (4") above top of finished permeable wearing course or overburden. |
− | (3)<b> Primary Surface Reglet: </b>Install as detailed with steel channel and concrete pins. Adhered membrane termination held in place by clamping pressure and pins. | + | (3) <b> Primary Surface Reglet: </b>Install as detailed with steel channel and concrete pins. Adhered membrane termination held in place by clamping pressure and pins. |
− | (4)<b> Fasteners: </b>Suitable expanding type concrete pins. | + | (4) <b> Fasteners: </b>Suitable expanding type concrete pins. |
− | (5)<b> Clamping Bar: </b>Steel channel with elongated holes to permit expansion/contraction, pinned into concrete at maximum 400 mm (16") o/c. Bar dimensions to be a minimum 38 mm (1 ½") wide x 12 mm (1/2") thick C-channel, formed from a minimum 22 gauge galvanized or pre-finished steel. | + | (5) <b> Clamping Bar: </b>Steel channel with elongated holes to permit expansion/contraction, pinned into concrete at maximum 400 mm (16") o/c. Bar dimensions to be a minimum 38 mm (1 ½") wide x 12 mm (1/2") thick C-channel, formed from a minimum 22 gauge galvanized or pre-finished steel. |
− | (6)<b> Caulking: </b>Polyurethane sealant, fill to top of the flashing and crown to promote drainage.(7)<b> Surface Reglet Counter Flashing: </b>To cover lower reglet assembly, pinned directly without a clamping bar at maximum 300 mm (12") o/c. (Interlocking hooked type assembly optional) | + | (6) <b> Caulking: </b>Polyurethane sealant, fill to top of the flashing and crown to promote drainage.(7)<b> Surface Reglet Counter Flashing: </b>To cover lower reglet assembly, pinned directly without a clamping bar at maximum 300 mm (12") o/c. (Interlocking hooked type assembly optional) |
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | (A)<b>Concrete, Stone or Steel Wall Finish:</b> Must be dry, smooth and primed for membrane flashing to be adhered directly. (Plywood or fibre-mat reinforced cement board may be required). | + | (A) <b>Concrete, Stone or Steel Wall Finish:</b> Must be dry, smooth and primed for membrane flashing to be adhered directly. (Plywood or fibre-mat reinforced cement board may be required). |
<b>NOTE: * AVOID SURFACE REGLET: (wherever possible) Use preformed or saw cut REGLETS:</b> | <b>NOTE: * AVOID SURFACE REGLET: (wherever possible) Use preformed or saw cut REGLETS:</b> | ||
− | + | </div><!-- COL-6-MD --> | |
+ | </div><!-- PANEL BODY --> | ||
+ | </div><!-- PANEL --> | ||
+ | |||
+ | '''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements. | ||
<hr> | <hr> | ||
Line 30: | Line 40: | ||
− | |||
− | [[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[Section:F. Application: Waterproofing Plazas, Promenades and Terraces|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Application'']] |
+ | |||
+ | [[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Construction Details'']] | ||
− | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']] |
Revision as of 21:50, 19 August 2016
1 WORK INCLUDED
(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab depicted), installed as per RGC Guarantee Standards E and Membrane Manufacturer's installation specifications.
(2) Membrane Flashing: Carried up wall minimum 200 mm (8") above deck surface and minimum 100 mm (4") above top of finished permeable wearing course or overburden.
(3) Primary Surface Reglet: Install as detailed with steel channel and concrete pins. Adhered membrane termination held in place by clamping pressure and pins.
(4) Fasteners: Suitable expanding type concrete pins.
(5) Clamping Bar: Steel channel with elongated holes to permit expansion/contraction, pinned into concrete at maximum 400 mm (16") o/c. Bar dimensions to be a minimum 38 mm (1 ½") wide x 12 mm (1/2") thick C-channel, formed from a minimum 22 gauge galvanized or pre-finished steel.
(6) Caulking: Polyurethane sealant, fill to top of the flashing and crown to promote drainage.(7) Surface Reglet Counter Flashing: To cover lower reglet assembly, pinned directly without a clamping bar at maximum 300 mm (12") o/c. (Interlocking hooked type assembly optional)
2 RELATED WORK BY OTHERS
(A) Concrete, Stone or Steel Wall Finish: Must be dry, smooth and primed for membrane flashing to be adhered directly. (Plywood or fibre-mat reinforced cement board may be required).
NOTE: * AVOID SURFACE REGLET: (wherever possible) Use preformed or saw cut REGLETS:
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
Back to Waterproofing Application