Difference between revisions of "SBS Canted Edge"

Jump to: navigation, search

Difference between revisions of "SBS Canted Edge"

(Created page with "<hr> File:D1.7.2.1.jpg File:D1.7.2.2.jpg === WORK INCLUDED === ;(1) Vapor Retarder: :If required by design authority. ;(2) Insulation: :Mechanically fastened where...")
 
(RELATED WORK BY OTHERS)
Line 31: Line 31:
 
;(C)  Wood Blocking:  
 
;(C)  Wood Blocking:  
 
:Equal to height of insulation and overlay board, primed wherever in contact with asphalt.
 
:Equal to height of insulation and overlay board, primed wherever in contact with asphalt.
 +
  
 
NOTE: Refer to <i>RGC Guarantee Standards</i> for additional requirements.
 
NOTE: Refer to <i>RGC Guarantee Standards</i> for additional requirements.
 +
  
 
<hr>
 
<hr>

Revision as of 20:11, 19 July 2016


File:D1.7.2.1.jpg

File:D1.7.2.2.jpg


1 WORK INCLUDED

(1) Vapor Retarder
If required by design authority.
(2) Insulation
Mechanically fastened where deck type permits. (See list of accepted materials in Section 2.2). (See Section 2.1.1 RGC Guarantee Standard A4.4
(3) Overlay Board
Asphalt adhered or mechanically fastened. Two layers required over heat-sensitive insulation. (See RGC Guarantee Standard C4.1)
(4) Base Sheet
Adhered to overlay board using asphalt, cold adhesive, self-adhered, mechanical attachment or torch applied according to manufacturer’s specification. Torching directly to wood surfaces is not permitted.
(5) Base Sheet Flashing
Adhered according to manufacturer’s specifications, using cold adhesive, hot asphalt self-adhered or torch applied to cover boards, or mechanically attached membrane. Must be carried over to outside of fascia. Torching directly to wood surfaces is not permitted. (See RGC Guarantee Standards Section 2.1.1, A5.6, and Section 2.1.3, C8.5).
(6) Cap Sheet
Applied according to manufacturer’s printed instructions and RGC Guarantee Standards.
(7) Cap Sheet Flashing
Applied according to manufacturer’s printed instructions and RGC Guarantee Standards up to the top of cant.
(8) Metal Flashing
As required by RGC Guarantee Standards. (See RGC Guarantee Standard A6.9 and A6.10)


2 RELATED WORK BY OTHERS

(A) Acceptable Deck
Smooth, dry and clean.
(B) Fascia
Optional.
(C) Wood Blocking
Equal to height of insulation and overlay board, primed wherever in contact with asphalt.


NOTE: Refer to RGC Guarantee Standards for additional requirements.




Back to SBS Application

Back to SBS Construction Details

Back to Construction Details