Difference between revisions of "Materials:NLSM LiteN'Less III"

Jump to: navigation, search

Difference between revisions of "Materials:NLSM LiteN'Less III"

 
Line 17: Line 17:
 
|
 
|
 
<div class="col-md-12">
 
<div class="col-md-12">
<div class="col-md-4">
+
<div class="col-md-6">
 
;:
 
;:
 
;'''Vegetated Roof System Manufacturer''': Name linked to website here
 
;'''Vegetated Roof System Manufacturer''': Name linked to website here
Line 23: Line 23:
 
;Accepted for application in: Vegetated Roof Systems
 
;Accepted for application in: Vegetated Roof Systems
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
 
;Acceptance Criteria: Refer to the [[VRA Standard | RGC Standard for Vegetated Roofs]]
<div style="text-align: left;">
+
;System Summary: The LiteN’Less™ III system is lightweight and soilless, with no “loose” growing medium, and utilizes three layers of water retention fleece while still offering solutions for roof retrofits.
[[File:Extensive VR System (sedum tile).jpg|class=img-responsive| link=https://rpm.rcabc.org/images/d/d7/Extensive_VR_System_%28sedum_tile%29.jpg]]
+
<div style="text-align:left;">
 +
[[File:Extensive VR System (sedum tile).jpg| left | 450 px| link=]]
 
</div>
 
</div>
 
</div>
 
</div>
 
<div class="col-md-6">
 
<div class="col-md-6">
 
;:
 
;:
;System Summary: description here, using <br>breaks
+
;Manufacturer Online Resource: [https://www.nlsm.ca/systems-technical-info-2/extensive-systems/litenless-classic-iii/ LiteN'Less III System]
;System Depth: give range
+
;System Depth: 45.0 mm (1-13/16") to 62.0 mm (2-7/16")
;Growing Media Depth: give range
+
;Growing Media Depth: 20 mm (13/16")
;Vegetation Profile: give manufacturer's profile name or description
+
;Vegetation Profile: Moss-Sedum
;Suitable climate zones: give range or list zone numbers
+
;Suitable climate zones: All BC zones except Zone 4, subject to manufacturer's approval
 
;System Components:
 
;System Components:
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
:'''NL718 Sedum Blanket''' (Click [https://rpm.rcabc.org/images/b/bd/NLSM_NL718_Sedum_Blanket_-_Standard_Mix_BC_TDS.pdf here] for the Technical Data Sheet PDF)
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
:'''NL512 Retention Fleece''' (Click [https://rpm.rcabc.org/images/a/a7/NLSM_NL512_Retention_Fleece_TDS.pdf here] for the Technical Data Sheet PDF)
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
:'''NL512 Retention Fleece'''
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
:'''NL512 Retention Fleece''' (Note that this system requires three (3) layers of fleece)
:Component name (Click [link here] for the Technical Data Sheet PDF)
+
:'''NL300 Drainage Mat''' (Conventional Roof) (Click [https://rpm.rcabc.org/images/4/40/NLSM_NL300_Drainage_Mat_TDS.pdf here] for the Technical Data Sheet PDF) or Stone Ballast (PMRA)
 +
:'''NL120 Root Barrier''' (Click [https://rpm.rcabc.org/images/3/32/NLSM_NL120_Root_Barrier_TDS.pdf here] for the Technical Data Sheet PDF)
 +
:'''NL200 Edging & Accessories''' (Click [https://rpm.rcabc.org/images/9/96/NLSM_NL200_Edging_and_Accessories_TDS.pdf here] for the Technical Data Sheet PDF)
 +
:'''NL210 Drain Box & Accessories'''
 +
:'''NL220 Penetration Box'''
 +
 
 +
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
  
;Conditions and Limitations: description here, using <br>breaks
+
:Also note that vegetation coverage under the '''''RoofStar Vegetated Roof Guarantee''''' applies only to ''extensive systems'' planted with mats or trays - see [https://rpm.rcabc.org/index.php?title=Guarantee Part 3] of Division A for more about coverage.
 
</div>
 
</div>
 
</div>
 
</div>
 +
<div class="col-md-12">
 +
<br>
 
|}
 
|}
  

Latest revision as of 19:14, 21 November 2024



Division C - Accepted Materials
Group - Vegetated Roof Systems


NLSM LiteN'Less III
by Next Level Stormwater Management

System/Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Vegetated Roof System Manufacturer
Name linked to website here
Accepted for the RoofStar Guarantee Program
October 25, 2024
Accepted for application in
Vegetated Roof Systems
Acceptance Criteria
Refer to the RGC Standard for Vegetated Roofs
System Summary
The LiteN’Less™ III system is lightweight and soilless, with no “loose” growing medium, and utilizes three layers of water retention fleece while still offering solutions for roof retrofits.
Extensive VR System (sedum tile).jpg
Manufacturer Online Resource
LiteN'Less III System
System Depth
45.0 mm (1-13/16") to 62.0 mm (2-7/16")
Growing Media Depth
20 mm (13/16")
Vegetation Profile
Moss-Sedum
Suitable climate zones
All BC zones except Zone 4, subject to manufacturer's approval
System Components
NL718 Sedum Blanket (Click here for the Technical Data Sheet PDF)
NL512 Retention Fleece (Click here for the Technical Data Sheet PDF)
NL512 Retention Fleece
NL512 Retention Fleece (Note that this system requires three (3) layers of fleece)
NL300 Drainage Mat (Conventional Roof) (Click here for the Technical Data Sheet PDF) or Stone Ballast (PMRA)
NL120 Root Barrier (Click here for the Technical Data Sheet PDF)
NL200 Edging & Accessories (Click here for the Technical Data Sheet PDF)
NL210 Drain Box & Accessories
NL220 Penetration Box
*Conditions and Limitations
Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the vegetated roof system manufacturer for options and saturated system weight.
Also note that vegetation coverage under the RoofStar Vegetated Roof Guarantee applies only to extensive systems planted with mats or trays - see Part 3 of Division A for more about coverage.



Back to Accepted Materials

Home