Difference between revisions of "Materials:ZinCo Sedum Roof"

Jump to: navigation, search

Difference between revisions of "Materials:ZinCo Sedum Roof"

 
Line 37: Line 37:
 
;:
 
;:
 
;Manufacturer Online Resource: [https://www.zinco.ca/sedum-roof ZinCo Sedum Roof]
 
;Manufacturer Online Resource: [https://www.zinco.ca/sedum-roof ZinCo Sedum Roof]
;System Depth: 101.6 mm (4") to 127 mm (5")
+
;System Type: Extensive
 +
;System Depth<sup>*</sup>: 101.6 mm (4") to 127 mm (5")
 
;Growing Media Depth: 80 mm (3-1/8") to 80 mm (3-1/8")
 
;Growing Media Depth: 80 mm (3-1/8") to 80 mm (3-1/8")
 
;Vegetation Profile: Succulents-Sedums
 
;Vegetation Profile: Succulents-Sedums
 
;Suitable climate zones: All BC zones (except Zone 6), subject to manufacturer's approval
 
;Suitable climate zones: All BC zones (except Zone 6), subject to manufacturer's approval
;System Components: (in the usual order, from top to bottom)
+
;System Components<sup>*</sup>: In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
*'''Sedums''' (pre-grown mats & plugs) (Click [link here] for the Technical Data Sheet PDF)
+
:*'''Sedums''' (pre-grown mats & plugs)
*'''Blend-E Growing Medium''' (Click [https://rpm.rcabc.org/images/8/86/ZinCo_System_Growing_Medium_%28ZinCo_Blend-E%29_TDS.pdf here] for the Technical Data Sheet PDF)
+
:**[https://rpm.rcabc.org/images/3/38/ZinCo_Plug_Plants_Sedum_Carpet_TDS.pdf '''ZinCo Plugs and Sedum Carpets'''] and
*'''Filter Sheet SF''' (for alternate drainage board FD25) (Click [https://rpm.rcabc.org/images/9/91/ZinCo_Filter_Sheet_SF_TDS.pdf here] for the Technical Data Sheet PDF)
+
:**[https://rpm.rcabc.org/images/8/87/ZinCo_Pre-cultivated_Vegetation_Mats_TDS.pdf '''ZinCo pre-cultivated vegetation mats''']
*'''Fixodrain XD20''' (drainage board) (Click [https://rpm.rcabc.org/images/8/80/ZinCo_Fixodrain_XD20_TDS.pdf here] for the Technical Data Sheet PDF)
+
:*[https://rpm.rcabc.org/images/8/86/ZinCo_System_Growing_Medium_%28ZinCo_Blend-E%29_TDS.pdf '''Blend-E Growing Medium''']
*'''DBV-10''' (alternate drainage board)(Click [https://rpm.rcabc.org/images/3/3d/ZinCo_Drainage_Mat_DBV10_TDS.pdf here] for the Technical Data Sheet PDF)
+
:*[https://rpm.rcabc.org/images/9/91/ZinCo_Filter_Sheet_SF_TDS.pdf '''Filter Sheet SF''']
*'''Floradrain FD25-E''' (alternate drainage board) (Click [https://rpm.rcabc.org/images/7/75/ZinCo_Floradrain_FD25-E_TDS.pdf here] for the Technical Data Sheet PDF)
+
:*[https://rpm.rcabc.org/images/8/80/ZinCo_Fixodrain_XD20_TDS.pdf '''Fixodrain XD20'''] (drainage board)
*'''Protection Mat TSM32''' (Click [https://rpm.rcabc.org/images/c/c5/ZinCo_Protection_Mat_TSM32_TDS.pdf here] for the Technical Data Sheet PDF)
+
:**[https://rpm.rcabc.org/images/7/75/ZinCo_Floradrain_FD25-E_TDS.pdf '''Floradrain FD25-E'''] (alternate drainage board)
*'''Root Barrier WSF40''' (Click [https://rpm.rcabc.org/images/0/09/ZinCo_Root_Barrier_WSF40_TDS.pdf here] for the Technical Data Sheet PDF)
+
:**[https://rpm.rcabc.org/images/3/3d/ZinCo_Drainage_Mat_DBV10_TDS.pdf '''DBV-10'''] (alternate drainage board)
*'''Edging Profile DP125 / DP100''' (Click [https://rpm.rcabc.org/images/8/86/ZinCo_Eaves_Profile_DP125_TDS.pdf here] for the DP125 Technical Data Sheet PDF; click [https://rpm.rcabc.org/images/1/1d/ZinCo_Eaves_Profile_DP100_TDS.pdf here] for the DP100 Technical Data Sheet PDF))
+
:*[https://rpm.rcabc.org/images/c/c5/ZinCo_Protection_Mat_TSM32_TDS.pdf '''Protection Mat TSM32''']
*'''Inspection Chamber KS10/30''' (Click [https://rpm.rcabc.org/images/7/79/ZinCo_Inspection_Chamber_KS10%2BKS10-GR_TDS.pdf here] for the Technical Data Sheet PDF)
+
:*[https://rpm.rcabc.org/images/0/09/ZinCo_Root_Barrier_WSF40_TDS.pdf '''Root Barrier WSF40''']
*'''Extension Piece KSA8'''
+
::'''Conventionally Insulated Roof Assembly''' by roofing ''Contractor''
<br>
+
 
 +
:*[https://rpm.rcabc.org/images/8/86/ZinCo_Eaves_Profile_DP125_TDS.pdf '''Edging Profile DP125'''] and [https://rpm.rcabc.org/images/1/1d/ZinCo_Eaves_Profile_DP100_TDS.pdf '''Edging Profile DP100''']
 +
:*[https://rpm.rcabc.org/images/7/79/ZinCo_Inspection_Chamber_KS10%2BKS10-GR_TDS.pdf '''Inspection Chamber KS10/30''']
 +
:*'''Extension Piece KSA8'''
 +
 
 
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
 
;<sup>*</sup>Conditions and Limitations: Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements.  Consult with the ''vegetated roof system manufacturer'' for options and saturated system weight.
  

Latest revision as of 18:44, 25 November 2024



Division C - Accepted Materials
Group - Vegetated Roof Systems


ZinCo Sedum Roof
by ZinCo Canada Inc.

System/Material Acceptance and Product Details


The information published in the RCABC Roofing Practices Manual and offered below does NOT represent a complete set of the manufacturer’s data or specifications, nor is this system and its various materials recommended or endorsed by the Guarantor. The preparation of a detailed specification is the responsibility of the Design Authority.

Vegetated Roof System Manufacturer
ZinCo Canada Inc.
Accepted for the RoofStar Guarantee Program
October 25, 2024
Accepted for application in
Vegetated Roof Systems
Acceptance Criteria
Refer to the RGC Standard for Vegetated Roofs
System Summary
With a plant palette consisting of hardy, drought tolerant sedum species, this is the green roof system designed by ZinCo Canada Inc. for low cost and simple installation. It is lightweight and offers low maintenance requirements. Colourful and long lasting, the ZinCo Sedum Roof system features:
  • Compact & Lightweight
  • Low maintenance
  • Only 60-80 mm of growing medium required
  • Flexible planting methods, and
  • Easy Installation
(adapted from the manufacturer's literature).
Extensive VR System (sedum tile).jpg
Manufacturer Online Resource
ZinCo Sedum Roof
System Type
Extensive
System Depth*
101.6 mm (4") to 127 mm (5")
Growing Media Depth
80 mm (3-1/8") to 80 mm (3-1/8")
Vegetation Profile
Succulents-Sedums
Suitable climate zones
All BC zones (except Zone 6), subject to manufacturer's approval
System Components*
In the usual order, from top to bottom; click on link for Technical Data Sheet (TDS)
Conventionally Insulated Roof Assembly by roofing Contractor
*Conditions and Limitations
Note that system thickness is dependent upon the selection of components, which is determined (in part) by design parameters, including hydrological requirements. Consult with the vegetated roof system manufacturer for options and saturated system weight.
Also note that vegetation coverage under the RoofStar Vegetated Roof Guarantee applies only to extensive systems planted with mats or trays - see Part 3 of Division A for more about coverage.



Back to Accepted Materials

Home