=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSSUBSTRATES|'''Gypsum Board''']]: | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSSUBSTRATES|'''1. Gypsum Board''']]: |
:If required by design authority. | :If required by design authority. | ||
− | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSVAPOUR|'''Vapour Retarder''']]: | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSVAPOUR|'''2. Vapour Retarder''']]: |
:If required by design authority. | :If required by design authority. | ||
− | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSINSULATION|'''Insulation''']]: | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSINSULATION|'''3. Insulation''']]: |
:See list of '''[[Section:C. Accepted Materials|Accepted Materials]]'''. | :See list of '''[[Section:C. Accepted Materials|Accepted Materials]]'''. | ||
− | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSINSULATIONOVERLAY|'''Insulation Overlay Board''']]: | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSINSULATIONOVERLAY|'''4. Insulation Overlay Board''']]: |
:As required. | :As required. | ||
− | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSBASE|'''Primary Membrane and Membrane Protection''']]: | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSBASE|'''5. Primary Membrane and Membrane Protection''']]: |
− | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''Membrane Flashing''']]: | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''6. Membrane Flashing''']]: |
:Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge. See '''Perimeter Flashings: Membrane''' for RoofStar Guarantee Standards. | :Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge. See '''Perimeter Flashings: Membrane''' for RoofStar Guarantee Standards. | ||
− | ;[[RoofStar Guarantee Standards for SBS Roof Systems#METALBASE-SBS|'''Metal Base Flashing''']]: | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#METALBASE-SBS|'''7. Metal Base Flashing''']]: |
:Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats. | :Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats. | ||
− | ;[[RoofStar Guarantee Standards for SBS Roof Systems#METALCAP-SBS|'''Metal Cap Flashing''']]: | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#METALCAP-SBS|'''8. Metal Cap Flashing''']]: |
:Flashings 1 and 2 may be one piece. Fasten with continuous concealed clip-type fasteners <b>or</b> cladding screws evenly spaced between seams. See '''Perimeter Metal Flashings''' for requirements. | :Flashings 1 and 2 may be one piece. Fasten with continuous concealed clip-type fasteners <b>or</b> cladding screws evenly spaced between seams. See '''Perimeter Metal Flashings''' for requirements. | ||
Revision as of 22:07, 18 July 2016
1 WORK INCLUDED
- 1. Gypsum Board
- If required by design authority.
- 2. Vapour Retarder
- If required by design authority.
- 3. Insulation
- See list of Accepted Materials.
- 4. Insulation Overlay Board
- As required.
- 5. Primary Membrane and Membrane Protection
- 6. Membrane Flashing
- Mechanically fasten to outside face of parapet blocking (D). At least one ply must extend over outside edge. See Perimeter Flashings: Membrane for RoofStar Guarantee Standards.
- 7. Metal Base Flashing
- Optional on flexible membrane systems. Required on assemblies using gravel ballast filter mats.
- 8. Metal Cap Flashing
- Flashings 1 and 2 may be one piece. Fasten with continuous concealed clip-type fasteners or cladding screws evenly spaced between seams. See Perimeter Metal Flashings for requirements.
2 RELATED WORK BY OTHERS
(A) Acceptable Deck
(B) Air / Vapour Seal
(C) Acceptable Wall Surface
(D) Wood Blocking
(E) Sloped Wood Blocking: Required over 100 mm (4") parapet width. See RGC Guarantee Standard A6.9
NOTE: Refer to RGC Guarantee Standards for additional requirements.]