Difference between revisions of "EPDM Conventionally Insulated System (Alternate)"

Jump to: navigation, search

Difference between revisions of "EPDM Conventionally Insulated System (Alternate)"

(RELATED WORK BY OTHERS)
Line 4: Line 4:
  
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
(1) <b>Vapour Retardant:</b> If required by design authority.
+
;(1) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMVAPOUR|'''Vapour Retarder''']]: If required by design authority.
 
+
;(2) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMINSULATION|'''Insulation''']]: Mechanically attached where deck type permits. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual.
(2) <b>Insulation: </b>Mechanically attached where deck type permits. Installed according to <i>RGC</i> <i>Guarantee Standard </i>A4.3.<i> </i>See Section 2.2 for accepted materials
+
;(3) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMADHESIVE|'''Adhesive''']]: Proprietary, installed according to manufacturer's instructions, usually brushed, rolled or sprayed.
 
+
;(4) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMMEMBRANE|'''Single-ply Membrane''']]: Installed according to manufacturer's instructions and ''RoofStar Guarantee Standards''.
(3) <b>Adhesive: </b>Proprietary, installed according to manufacturer&#8217;s instructions, usually brushed, rolled or sprayed.
+
;(5) '''Membrane Lap''': Thermoset membrane may be joined using uncured tape or proprietary adhesive.
 
+
;(6) '''Edge Flashing''': Proprietary.
(4) <b>Single Ply Membrane:</b> Installed according to manufacturer&#8217;s instructions and <i>RGC</i> <i>Guarantee Standards </i>Section<i> </i>2.1.1 and Section 2.1.3.
+
;(7) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMSTRIPPING|'''Membrane Flashing''']]: Installed according to manufacturer's instructions.
 
 
(5) <b>Membrane Lap: </b>Thermoplastic membrane may be welded or chemically bonded (See Section 6.2) Thermoset membrane may be joined using uncured tape or proprietary adhesive (See Section 6.1).
 
 
 
(6) <b>Edge Flashing:</b> Proprietary.
 
 
 
(7) <b>Membrane Flashing:</b> Installed according to manufacturer&#8217;s instructions.
 
  
 +
<hr>
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
(A) <b>Acceptable Deck</b>
+
;(A) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMDECKS|'''Acceptable Deck''']]
 +
;(B) '''Fascia''': Optional.
 +
;(C) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMWOODBLOCKING|'''Wood Blocking''']]
  
(B) <b>Fascia:</b> Optional.
 
  
(C) <b>Wood Blocking:</b> Equal to height of insulation.
 
  
 +
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
  
'''NOTE''': Refer to <i>RGC Guarantee Standards</i> for additional requirements.
 
  
 +
<hr>
  
<hr>
 
  
  

Revision as of 15:45, 8 August 2016


6.3.2.1.jpg


1 WORK INCLUDED

(1) Vapour Retarder
If required by design authority.
(2) Insulation
Mechanically attached where deck type permits. Installed according to RoofStar Guarantee Standards. See available insulation products in the Accepted Materials section of this Manual.
(3) Adhesive
Proprietary, installed according to manufacturer's instructions, usually brushed, rolled or sprayed.
(4) Single-ply Membrane
Installed according to manufacturer's instructions and RoofStar Guarantee Standards.
(5) Membrane Lap
Thermoset membrane may be joined using uncured tape or proprietary adhesive.
(6) Edge Flashing
Proprietary.
(7) Membrane Flashing
Installed according to manufacturer's instructions.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Fascia
Optional.
(C) Wood Blocking


NOTE: Refer to RoofStar Guarantee Standards for additional requirements.





Back to EPDM Application

Back to EPDM Construction Details

Back to Construction Details