=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ; | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSBASE|'''Base Sheet''']]: |
− | :Adhered to deck using asphalt, cold adhesive, self-adhered, torch applied membrane or loose laid according to manufacturer | + | :Adhered to deck using asphalt, cold adhesive, self-adhered, torch applied membrane or loose laid according to manufacturer's specification and to the <i>RoofStar Guarantee Standards</i>. |
− | ; | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''Base Sheet Flashing''']]: |
− | :Adhered according to manufacturer | + | :Adhered according to manufacturer's specifications using cold adhesive, self-adhered or torch applied to cover boards, or mechanically attached membrane. Torching directly to wood surfaces is not permitted. Must be carried over to outside of parapet or minimum 200 mm (8") above finished roof surface (see RoofStar Guarantee Standards for SBS Roofing Systems, [[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''10.3''']]. |
− | ; | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSBASE|'''Cap Sheet''']]: |
:Applied according to manufacturer’s printed instructions and <i>RGC Guarantee Standards</i>. | :Applied according to manufacturer’s printed instructions and <i>RGC Guarantee Standards</i>. | ||
− | ; | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBS-STRIPPING|'''Cap Sheet Flashing''']]: |
:Applied according to manufacturer’s printed instructions and <i>RGC Guarantee Standards</i> to top of parapet or minimum 200 mm (8") above top of finished roof surface. | :Applied according to manufacturer’s printed instructions and <i>RGC Guarantee Standards</i> to top of parapet or minimum 200 mm (8") above top of finished roof surface. | ||
− | ; | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSINSULATION|'''Insulation''']]: |
− | :See | + | :See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. |
− | ; | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSFILTER|'''Filter Fabric''']]: |
− | :Metal base flashing required. | + | :Metal base flashing required. See ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSMETAL|'''Section 12''']]. |
− | ; | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSBALLAST|'''Ballast''']]: |
− | :Gravel or concrete paving tiles. | + | :Gravel or concrete paving tiles. |
− | + | ;[[RoofStar Guarantee Standards for SBS Roof Systems#SBSMETAL|'''Metal Flashing''']]: | |
− | :As required by <i>RGC</i> <i>Guarantee Standards</i>. | + | :As required by <i>RGC</i> <i>Guarantee Standards</i>. |
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === |
Revision as of 19:14, 29 July 2016
1 WORK INCLUDED
- Base Sheet
- Adhered to deck using asphalt, cold adhesive, self-adhered, torch applied membrane or loose laid according to manufacturer's specification and to the RoofStar Guarantee Standards.
- Base Sheet Flashing
- Adhered according to manufacturer's specifications using cold adhesive, self-adhered or torch applied to cover boards, or mechanically attached membrane. Torching directly to wood surfaces is not permitted. Must be carried over to outside of parapet or minimum 200 mm (8") above finished roof surface (see RoofStar Guarantee Standards for SBS Roofing Systems, 10.3.
- Cap Sheet
- Applied according to manufacturer’s printed instructions and RGC Guarantee Standards.
- Cap Sheet Flashing
- Applied according to manufacturer’s printed instructions and RGC Guarantee Standards to top of parapet or minimum 200 mm (8") above top of finished roof surface.
- Insulation
- See available insulation products in the Accepted Materials section of this Manual.
- Filter Fabric
- Metal base flashing required. See ;Section 12.
- Ballast
- Gravel or concrete paving tiles.
- Metal Flashing
- As required by RGC Guarantee Standards.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- Smooth, dry and clean concrete, coated with proprietary primer.
- (B) Plywood Backing
- Required on rough concrete or where stripping adhesion is asphalt. Must be primed.
- (C) Wood Blocking
- Sloped to roof where parapet is over 100 mm (4") in width.
NOTE: Refer to RGC Guarantee Standards for additional requirements.