Difference between revisions of "TPO Conventionally Insulated System (Alternate)"
Difference between revisions of "TPO Conventionally Insulated System (Alternate)"
(Created page with "File:6.3.2.1.jpg === WORK INCLUDED === (1) <b>Vapour Retardant: </b>If required by design authority (2) <b>Insulation: </b>Mechanically fastened where deck type permits...") |
|||
Line 3: | Line 3: | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | (1) | + | ;(1) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOVAPOUR|'''Vapour Retarder''']]: If required by design authority |
+ | ;(2) [[RoofStar Guarantee Standards for EPDM Roof Systems#EPDMINSULATION|'''Insulation''']]: Mechanically fastened where deck type permits, or fully adhered (as illustrated). Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. | ||
+ | ;(3) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOADHESIVE|'''Adhesive''']]: | ||
+ | Proprietary, installed according to manufacturer’s instructions, usually brushed, rolled or sprayed (3A: 2- part low rising insulation adhesive, specifically used to bond insulation and cover boards) | ||
+ | ;(4) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOMEMBRANE|'''Single-ply Membrane''']]: Installed according to manufacturer’s instructions and ''RoofStar Guarantee Standards''. | ||
+ | ;(5) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOLAP|'''Membrane Lap''']]: Thermoplastic membrane may be welded or chemically bonded (See Section 6.2). Thermoplastic membrane may be welded or chemically bonded. | ||
+ | ;(6) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOEDGE|'''Edge Flashing''']]: Proprietary, coated with membrane material and heat-welded to the primary (field) membrane. | ||
+ | ;(7) '''Fascia Flashing Clip''': Affixed to the fascia material (installed by others) with fasteners O.C. 300 mm (12”) | ||
+ | ;(8) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOFASCIA|'''Fascia Flashing''']]: Manufactured to RoofStar Guarantee Standards for sheet metal flashings. | ||
+ | ;(9) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOSTRIPPING|'''Membrane Flashing''']]: Adhered according to manufacturer’s printed specifications using proprietary adhesive. Must be carried to the outside of the parapet or vertically to a minimum of 200 mm (8”) above the finished roof surface. Welded or adhered to primary membrane depending on membrane type. | ||
− | + | <hr> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | (A) | + | ;(A) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPODECKS|'''Acceptable Deck''']] |
− | + | ;(B) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOWALLSUB|'''Acceptable Parapet Surface''']]: Surface must be smooth, dry and clean. Rough surface must be covered with treated plywood, to be determined by design authority or inspector or as required by manufacturer. | |
− | (B) | + | ;(C) [[RoofStar Guarantee Standards for TPO/PVC Roof Systems#TPOWOODBLOCKING|'''Edge Blocking''']] |
− | + | (D) '''Fascia Material''' | |
− | (C) | ||
− | |||
− | (D) | ||
Revision as of 21:48, 8 August 2016
1 WORK INCLUDED
- (1) Vapour Retarder
- If required by design authority
- (2) Insulation
- Mechanically fastened where deck type permits, or fully adhered (as illustrated). Installed according to RoofStar Guarantee Standards. See available insulation products in the Accepted Materials section of this Manual.
- (3) Adhesive
Proprietary, installed according to manufacturer’s instructions, usually brushed, rolled or sprayed (3A: 2- part low rising insulation adhesive, specifically used to bond insulation and cover boards)
- (4) Single-ply Membrane
- Installed according to manufacturer’s instructions and RoofStar Guarantee Standards.
- (5) Membrane Lap
- Thermoplastic membrane may be welded or chemically bonded (See Section 6.2). Thermoplastic membrane may be welded or chemically bonded.
- (6) Edge Flashing
- Proprietary, coated with membrane material and heat-welded to the primary (field) membrane.
- (7) Fascia Flashing Clip
- Affixed to the fascia material (installed by others) with fasteners O.C. 300 mm (12”)
- (8) Fascia Flashing
- Manufactured to RoofStar Guarantee Standards for sheet metal flashings.
- (9) Membrane Flashing
- Adhered according to manufacturer’s printed specifications using proprietary adhesive. Must be carried to the outside of the parapet or vertically to a minimum of 200 mm (8”) above the finished roof surface. Welded or adhered to primary membrane depending on membrane type.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Acceptable Parapet Surface
- Surface must be smooth, dry and clean. Rough surface must be covered with treated plywood, to be determined by design authority or inspector or as required by manufacturer.
- (C) Edge Blocking
(D) Fascia Material
NOTE: Refer to RGC Guarantee Standards for additional requirements.