Difference between revisions of "SBS Protected Roof Assembly (typical)"
Difference between revisions of "SBS Protected Roof Assembly (typical)"
Line 9: | Line 9: | ||
[[File:D1.7.2.jpg|class=img-responsive]] | [[File:D1.7.2.jpg|class=img-responsive]] | ||
</div> | </div> | ||
+ | |||
+ | |||
+ | ::Click below for a printable version of this page. | ||
+ | |||
+ | <div style="width:150px; text-align: left;"> | ||
+ | :[[File:Pdf.png|100 px|link=http://rpm3.rcabc.org/images/c/c7/D1.7.1-2_SBS_Details_-_Assemblies_%28Protected_Assembly%29.pdf|'''Technical Data Sheet''']] | ||
+ | </div> | ||
+ | |||
</div><!-- COL-MD-6 --> | </div><!-- COL-MD-6 --> | ||
− | |||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === |
Revision as of 21:20, 22 September 2016
RoofStar Guarantee Standards are blue-linked |
SBS Details
1 WORK INCLUDED
- (1) Base Sheet
- Adhered to deck using asphalt, cold adhesive, self-adhered, torch applied membrane or loose laid according to manufacturer's specification and to the RoofStar Guarantee Standards.
- (2) Base Sheet Flashing
- Adhered according to manufacturer's specifications using cold adhesive, self-adhered or torch applied to cover boards, or mechanically attached membrane. Torching directly to wood surfaces is not permitted. Must be carried over to outside of parapet or minimum 200 mm (8") above finished roof surface (see RoofStar Guarantee Standards for SBS Roofing Systems, 10.3).
- (3) Cap Sheet
- Applied according to manufacturer’s printed instructions and RoofStar Guarantee Standards.
- (4) Cap Sheet Flashing
- Applied according to manufacturer’s printed instructions and RoofStar Guarantee Standards to top of parapet or minimum 200 mm (8") above top of finished roof surface.
- (5) Insulation
- See available insulation products in the Accepted Materials section of this Manual.
- (6) Filter Fabric
- Metal base flashing required. See Section 12.
- (7) Ballast
- Gravel or concrete paving tiles.
- (8) Metal Flashing
- As required by RoofStar Guarantee Standards.
- (9) Fire-stop Tape.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- Smooth, dry and clean concrete, coated with proprietary primer.
- (B) Plywood Backing
- Required on rough concrete or where stripping adhesion is asphalt. Must be primed.
- (C) Sloped Wood Blocking
- Sloped to roof where parapet is over 100 mm (4") in width.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.