RoofStar Guarantee Standards are blue-linked |
1 WORK INCLUDED
(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed a per RoofStar Guarantee Standards E and Membrane Manufacturer's installation specifications.
(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.
(3) Protection Board/Mat: Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with RoofStar Guarantee Standards E.
(4) Pedestal: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling.
(7) Pavers: Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24").
2 WORK BY OTHERS
(A) Acceptable Deck: Concrete slab depicted.
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.