Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"

Jump to: navigation, search

Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"

(WORK INCLUDED)
(WORK INCLUDED)
Line 14: Line 14:
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
  
(1) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMEMBRANE '''Primary Waterproofing Membrane''']: Fully adhered to acceptable substrates (concrete slab shown), installed as per the [[RoofStar Guarantee Standards for Waterproofing|'''RoofStar Guarantee Standards for Waterproofing''']] and the Membrane Manufacturer's installation specifications.
+
(1) [http://{{SERVERNAME}}/index.php?title=RoofStar_Guarantee_Standards_for_Waterproofing#WPMEMBRANE '''Primary Waterproofing Membrane''']: Fully adhered to acceptable substrates (concrete slab shown), installed as per the [[RoofStar Guarantee Standards for Waterproofing| '''RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces''']] and the Membrane Manufacturer's installation specifications.
  
 
(2) '''Membrane Primer or Adhesive''': Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.  
 
(2) '''Membrane Primer or Adhesive''': Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.  

Revision as of 18:24, 12 October 2016

RoofStar Guarantee Standards are blue-linked
Waterproofing Details for Plazas, Promenades and Terraces

9.6.2.jpg

1 WORK INCLUDED

(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per the RoofStar Guarantee Standards for Waterproofing Plazas, Promenades & Terraces and the Membrane Manufacturer's installation specifications.

(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.

(3) Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RoofStar Guarantee Standards.

(4) Drainage Medium: Proprietary (purpose-made) geocomposite drainage boards with synthetic water permeable fabric required to contain sand and gravel beds for unit masonry (pavers, bricks, and stone).

2 WORK BY OTHERS

(A) Acceptable Deck: Concrete slab depicted.

(B) Unit Masonry Wearing Coarse: Concrete brick, pavers, stone on sand and gravel or moror beds designed to support predicted live loads.

(C) Conductive Tape: Moisture Survey System (tape grid) mandatory and compliant with RoofStar Guarantee Standards. For RoofStar-accepted Moisture Survey Tape Systems, refer to MEMBRANE MOISTURE SURVEYS & MONITORING SENSOR GRIDS.

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.




Back to Waterproofing Application

Back to Waterproofing Construction Details

Back to Construction Details