Difference between revisions of "ASM Eave and Rake Edges (Mechanical Seams)"
Difference between revisions of "ASM Eave and Rake Edges (Mechanical Seams)"
(→RELATED WORK BY OTHERS) |
|||
Line 13: | Line 13: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[RoofStar Guarantee Standards for ASM Roof | + | ;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMICE|'''Ice and Water Protection''']]: Accepted self-adhered modified bituminous membrane. |
− | ;(2) [[RoofStar Guarantee Standards for ASM Roof | + | ;(2) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMSLIP|'''Slip Sheet''']]: Recommended over asphaltic underlays and / or as required by metal panel manufacturer. |
− | ;(3) [[RoofStar Guarantee Standards for ASM Roof | + | ;(3) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMCLIP|'''Metal Panel Clip''']]: Installed to metal roof panel manufacturer’s printed instructions. |
− | ;(4) [[RoofStar Guarantee Standards for ASM Roof | + | ;(4) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMPANEL |'''Architectural Metal Roof Panel''']] |
;(5) '''Continuous Metal Cleat''' | ;(5) '''Continuous Metal Cleat''' | ||
;(6) '''Metal Fascia Flashing''' | ;(6) '''Metal Fascia Flashing''' | ||
Line 24: | Line 24: | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[RoofStar Guarantee Standards for ASM | + | ;(A) [[RoofStar Guarantee Standards for ASM RoofAssemblies#ASMDECK|'''Acceptable Deck''']] |
− | ;(B) [[RoofStar Guarantee Standards for ASM Roof | + | ;(B) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMNAILER |'''Wood Nailer''']] |
;(C) '''Fascia Board''' | ;(C) '''Fascia Board''' | ||
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> |
Revision as of 17:11, 23 October 2017
RoofStar Guarantee Standards are blue-linked |
ASM Details
1 WORK INCLUDED
- (1) Ice and Water Protection
- Accepted self-adhered modified bituminous membrane.
- (2) Slip Sheet
- Recommended over asphaltic underlays and / or as required by metal panel manufacturer.
- (3) Metal Panel Clip
- Installed to metal roof panel manufacturer’s printed instructions.
- (4) Architectural Metal Roof Panel
- (5) Continuous Metal Cleat
- (6) Metal Fascia Flashing
- (7) Edge Metal Flashing (Continuous)
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Wood Nailer
- (C) Fascia Board
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
RoofStar Guarantee Standards for ASM Roof Systems