(WORK INCLUDED)
Line 23: Line 23:
 
<div class="col-md-6">
 
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope.  
+
;(1) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMUNDERLAYMENT|'''Underlayment''']]: The type of underlay required is determined by roof slope.  
;(2) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMSLIP|'''Slip Sheet''']]: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
+
;(2) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMSLIP|'''Slip Sheet''']]: Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
;(3) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMPANEL |'''Architectural Metal Roof Panel''']]
+
;(3) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMPANEL |'''Architectural Metal Roof Panel''']]
 
;(4) '''Flange''':  Set in two continuous beads of accepted caulking.  
 
;(4) '''Flange''':  Set in two continuous beads of accepted caulking.  
 
;(5) '''Preformed Penetration Collar'''
 
;(5) '''Preformed Penetration Collar'''
;(6) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLADSCREW |'''High-domed Gasketed Cladding-type Screws''']]: Flange fastened to manufacturer's specifications.  
+
;(6) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMCLADSCREW |'''High-domed Gasketed Cladding-type Screws''']]: Flange fastened to manufacturer's specifications.  
 
;(7) '''Seal Between Pipe And Flashing''': Continuous tooled bead of accepted caulking.  
 
;(7) '''Seal Between Pipe And Flashing''': Continuous tooled bead of accepted caulking.  
 
;(8) '''Stainless Steel Drawband'''  
 
;(8) '''Stainless Steel Drawband'''  
Line 36: Line 36:
  
 
=== RELATED WORK BY OTHERS ===
 
=== RELATED WORK BY OTHERS ===
;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']]
+
;(A) [[RoofStar Guarantee Standards for ASM Roof Assemblies#ASMDECK|'''Acceptable Deck''']]
 
;(B) '''Location Of Penetrations''': Must not interfere with standing seams or trapezoidal and intermediate ribs.  
 
;(B) '''Location Of Penetrations''': Must not interfere with standing seams or trapezoidal and intermediate ribs.  
 
;(C) '''Opening In Roof Deck''': Must be large enough to allow for thermal movement of metal roof panels.  
 
;(C) '''Opening In Roof Deck''': Must be large enough to allow for thermal movement of metal roof panels.  

Revision as of 17:16, 23 October 2017

RoofStar Guarantee Standards are blue-linked
ASM Details

ASM 11.1.1.jpg


Click below for a printable version of this page.
Pdf.png


1 WORK INCLUDED

(1) Underlayment
The type of underlay required is determined by roof slope.
(2) Slip Sheet
Recommended over asphaltic underlays and / or as required by metal roof panel manufacturer.
(3) Architectural Metal Roof Panel
(4) Flange
Set in two continuous beads of accepted caulking.
(5) Preformed Penetration Collar
(6) High-domed Gasketed Cladding-type Screws
Flange fastened to manufacturer's specifications.
(7) Seal Between Pipe And Flashing
Continuous tooled bead of accepted caulking.
(8) Stainless Steel Drawband
(9) Water Tight Back Up Storm Collar
Installed where practical.

2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Location Of Penetrations
Must not interfere with standing seams or trapezoidal and intermediate ribs.
(C) Opening In Roof Deck
Must be large enough to allow for thermal movement of metal roof panels.
(D) Pipe Or Support Stand

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.



RoofStar Guarantee Standards for ASM Roof Systems

Back to ASM Construction Details

Back to Construction Details