=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;1) [[RoofStar Guarantee Standards for TPO | + | ;1) [[RoofStar Guarantee Standards for TPO Membrane Systems#TPOSUBSTRATES|'''Gypsum Deck Overlay''']]: May be required depending on insulation thickness or when required as a thermal barrier by design authority. |
− | ;(2) [[RoofStar Guarantee Standards for TPO | + | ;(2) [[RoofStar Guarantee Standards for TPO Membrane Systems#TPOINSULATION|'''Insulation''']]: Mechanically attached. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Roof Deck Insulation|'''Accepted Materials''']] section of this Manual. |
− | ;(3) [[RoofStar Guarantee Standards for TPO | + | ;(3) [[RoofStar Guarantee Standards for TPO Membrane Systems#TPOMEMBRANE|'''Single-ply Membrane''']]: Installed according to manufacturer's instructions and ''RoofStar Guarantee Standards''. |
− | ;(4) [[RoofStar Guarantee Standards for TPO | + | ;(4) [[RoofStar Guarantee Standards for TPO Membrane Systems#TPOADHESIVE|'''Adhesive''']]: Proprietary, installed according to manufacturer's instructions, usually brushed, rolled or sprayed. |
− | ;(5) [[RoofStar Guarantee Standards for TPO | + | ;(5) [[RoofStar Guarantee Standards for TPO Membrane Systems#TPOSTRIPPING|'''Membrane Flashing''']]: Adhered according to manufacturer's printed specifications using proprietary adhesive. Must be carried to outside of parapet or minimum 200 mm (8") above finished roof surface. |
;(6) '''Fasteners''': Install according to manufacturer's instructions (style may vary depending on material type and manufacturer's specification). | ;(6) '''Fasteners''': Install according to manufacturer's instructions (style may vary depending on material type and manufacturer's specification). | ||
;(7) '''Membrane Lap''': Thermoplastic membrane may be welded or chemically bonded. | ;(7) '''Membrane Lap''': Thermoplastic membrane may be welded or chemically bonded. | ||
− | ;(8) [[RoofStar Guarantee Standards for TPO | + | ;(8) [[RoofStar Guarantee Standards for TPO Membrane Systems#METALCAP-TPO|'''Metal Cap Flashing''']]: As required by the ''RoofStar Guarantee Standards''. |
<hr> | <hr> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[RoofStar Guarantee Standards for TPO | + | ;(A) [[RoofStar Guarantee Standards for TPO Membrane Systems#TPODECKS|'''Acceptable Deck''']] |
− | ;(B) [[RoofStar Guarantee Standards for TPO | + | ;(B) [[RoofStar Guarantee Standards for TPO Membrane Systems#TPOWALLSUB|'''Acceptable Parapet Surface''']]: Surface must be smooth, dry and clean. Rough surface must be covered with treated plywood, to be determined by design authority or inspector or as required by manufacturer. |
− | ;(C) [[RoofStar Guarantee Standards for TPO | + | ;(C) [[RoofStar Guarantee Standards for TPO Membrane Systems#TPOWOODBLOCKING|'''Sloped Wood Blocking''']] |
</div><!-- COL-6-MD --> | </div><!-- COL-6-MD --> | ||
</div><!-- PANEL BODY --> | </div><!-- PANEL BODY --> |
Revision as of 19:14, 18 February 2020
RoofStar Guarantee Standards are blue-linked |
TPO Details
1 WORK INCLUDED
- 1) Gypsum Deck Overlay
- May be required depending on insulation thickness or when required as a thermal barrier by design authority.
- (2) Insulation
- Mechanically attached. Installed according to RoofStar Guarantee Standards. See available insulation products in the Accepted Materials section of this Manual.
- (3) Single-ply Membrane
- Installed according to manufacturer's instructions and RoofStar Guarantee Standards.
- (4) Adhesive
- Proprietary, installed according to manufacturer's instructions, usually brushed, rolled or sprayed.
- (5) Membrane Flashing
- Adhered according to manufacturer's printed specifications using proprietary adhesive. Must be carried to outside of parapet or minimum 200 mm (8") above finished roof surface.
- (6) Fasteners
- Install according to manufacturer's instructions (style may vary depending on material type and manufacturer's specification).
- (7) Membrane Lap
- Thermoplastic membrane may be welded or chemically bonded.
- (8) Metal Cap Flashing
- As required by the RoofStar Guarantee Standards.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Acceptable Parapet Surface
- Surface must be smooth, dry and clean. Rough surface must be covered with treated plywood, to be determined by design authority or inspector or as required by manufacturer.
- (C) Sloped Wood Blocking
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
RoofStar Guarantee Standards for TPO Membrane Systems