Difference between revisions of "EPDM Conventionally Insulated System (Alternate)"
Difference between revisions of "EPDM Conventionally Insulated System (Alternate)"
Line 15: | Line 15: | ||
<div class="col-md-6"> | <div class="col-md-6"> | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
− | ;(1) [[ | + | ;(1) [[EPDM Roof Systems Standard#EPDMAIRVAPOUR|'''Vapour Retarder''']]: If required by design authority. |
− | ;(2) [[ | + | ;(2) [[EPDM Roof Systems Standard#EPDMINSULATION|'''Insulation''']]: Mechanically attached where deck type permits. Installed according to ''RoofStar Guarantee Standards''. See available insulation products in the [[Insulation (Roof Waterproofing Systems)|'''Accepted Materials''']] section of this Manual. |
− | ;(3) [[ | + | ;(3) [[EPDM Roof Systems Standard#EPDMADHERED|'''Adhesive''']]: Proprietary, installed according to manufacturer's instructions, usually brushed, rolled or sprayed. |
− | ;(4) [[ | + | ;(4) [[EPDM Roof Systems Standard#EPDMMEMBRANES|'''Single-ply Membrane''']]: Installed according to manufacturer's instructions and ''RoofStar Guarantee Standards''. |
;(5) '''Membrane Lap''': Thermoset membrane may be joined using uncured tape or proprietary adhesive. | ;(5) '''Membrane Lap''': Thermoset membrane may be joined using uncured tape or proprietary adhesive. | ||
;(6) '''Edge Flashing''': Proprietary. | ;(6) '''Edge Flashing''': Proprietary. | ||
− | ;(7) [[ | + | ;(7) [[EPDM Roof Systems Standard#EPDMPERIMETERS|'''Membrane Flashing''']]: Installed according to manufacturer's instructions. |
<hr> | <hr> | ||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
− | ;(A) [[ | + | ;(A) [[EPDM Roof Systems Standard#EPDMDECKS|'''Acceptable Deck''']] |
;(B) Fascia: Optional. | ;(B) Fascia: Optional. | ||
;(C) Wood Blocking | ;(C) Wood Blocking | ||
Line 33: | Line 33: | ||
</div><!-- PANEL --> | </div><!-- PANEL --> | ||
− | + | '''NOTE''': See the [[EPDM Roof Systems Standard | '''Standard''']] for additional requirements. | |
− | '''NOTE''': | ||
<hr> | <hr> | ||
− | + | [[EPDM Roof Systems Standard|<i class="fa fa-chevron-circle-left fa" ></i> RoofStar Guarantee Standards for EPDM Membrane Systems]] | |
− | [[ | ||
[[EPDM (Thermoset Membranes) Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''EPDM Construction Details'']] | [[EPDM (Thermoset Membranes) Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''EPDM Construction Details'']] | ||
− | + | {{Tempate:RPM Page Footer with Copyright and Current Date}} |
Revision as of 14:28, 30 August 2021
RoofStar Guarantee Standards are blue-linked |
EPDM Details
1 WORK INCLUDED
- (1) Vapour Retarder
- If required by design authority.
- (2) Insulation
- Mechanically attached where deck type permits. Installed according to RoofStar Guarantee Standards. See available insulation products in the Accepted Materials section of this Manual.
- (3) Adhesive
- Proprietary, installed according to manufacturer's instructions, usually brushed, rolled or sprayed.
- (4) Single-ply Membrane
- Installed according to manufacturer's instructions and RoofStar Guarantee Standards.
- (5) Membrane Lap
- Thermoset membrane may be joined using uncured tape or proprietary adhesive.
- (6) Edge Flashing
- Proprietary.
- (7) Membrane Flashing
- Installed according to manufacturer's instructions.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Fascia
- Optional.
- (C) Wood Blocking
NOTE: See the Standard for additional requirements.
RoofStar Guarantee Standards for EPDM Membrane Systems
Back to EPDM Construction Details