Difference between revisions of "WP Details:F1.7.1(Wearing Course - Concrete Pavers)"
Difference between revisions of "WP Details:F1.7.1(Wearing Course - Concrete Pavers)"
(Created page with "<hr> File:9.6.1.jpg ;WORK INCLUDED (1)<b> Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed a per <i>RGC Guaran...") |
|||
Line 2: | Line 2: | ||
[[File:9.6.1.jpg]] | [[File:9.6.1.jpg]] | ||
− | + | ||
+ | ==== WORK INCLUDED ==== | ||
(1)<b> Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed a per <i>RGC Guarantee Standards E</i> and Membrane Manufacturer's installation specifications. | (1)<b> Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed a per <i>RGC Guarantee Standards E</i> and Membrane Manufacturer's installation specifications. | ||
Line 14: | Line 15: | ||
(7) <b>Concrete Paver: </b>Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24"). | (7) <b>Concrete Paver: </b>Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24"). | ||
− | |||
− | <i>(A) | + | ==== WORK BY OTHERS ==== |
+ | |||
+ | <i>(A)<b>Acceptable Deck</b>: Concrete slab depicted. | ||
<b><i>NOTE: </i>Refer to <i>RGC Guarantee Standards E</i> for additional requirements.</b> | <b><i>NOTE: </i>Refer to <i>RGC Guarantee Standards E</i> for additional requirements.</b> |
Revision as of 17:13, 23 December 2015
1 WORK INCLUDED
(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed a per RGC Guarantee Standards E and Membrane Manufacturer's installation specifications.
(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.
(3) Protection Board/Mat: Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards E.
(4) Pedestal: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling.
(7) Concrete Paver: Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24").
2 WORK BY OTHERS
(A)Acceptable Deck: Concrete slab depicted.