− | + | === WORK INCLUDED === | |
(1)<b> Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed a per <i>RGC Guarantee Standards E</i> and Membrane Manufacturer's installation specifications. | (1)<b> Primary Waterproofing Membrane:</b> Fully adhered to acceptable substrates (concrete slab shown), installed a per <i>RGC Guarantee Standards E</i> and Membrane Manufacturer's installation specifications. | ||
Line 13: | Line 13: | ||
(4) <b>Pedestal</b>: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling. | (4) <b>Pedestal</b>: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling. | ||
− | (7) <b>Concrete Paver: </b>Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24"). | + | (7) <b>Concrete Paver: </b>Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24"). |
− | |||
==== WORK BY OTHERS ==== | ==== WORK BY OTHERS ==== |
Revision as of 22:40, 23 December 2015
1 WORK INCLUDED
(1) Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed a per RGC Guarantee Standards E and Membrane Manufacturer's installation specifications.
(2) Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturers published application specifications.
(3) Protection Board/Mat: Proprietary membrane protection board or drainage board approved by membrane manufacture, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards E.
(4) Pedestal: Proprietary (purpose-made) pedestals, with integral spacer ribs for uniform spacing between pavers that provide a minimum 12.5 mm (1/2") of vertical separation layer for airflow and levelling. Alternative: drainage boards with sand and gravel beds for unit masonry designed to provide permeable layer and levelling.
(7) Concrete Paver: Designed to support predicted live loads, maximum size 200mm (24") by 200mm (24").
1.1 WORK BY OTHERS
(A)Acceptable Deck: Concrete slab depicted.
NOTE: Refer to RGC Guarantee Standards E for additional requirements.
Back to Waterproofing Application