− | {| class="wikitable" | style="color: black; background-color: orange; width: 100%;text-align:center"
| |
− | | colspan="2" | <big>'''''Notice to Reader'''''</big>
| |
− | |-
| |
− | | style="color: black; background-color: #ffffcc; width: 100%;text-align:center" | Images used in a Construction Detail are representative and <u>not intended in their representation of an assembly to be prescriptive</u>. Nor are they necessarily drawn to scale. Rather, they are provided to visually convey the Standards, Guiding Principles and Recommendations of the '''RoofStar Guarantee Standards''' for a Waterproofing or Water-shedding System. Actual design with respect to dimensions, the selection of materials and their application remains the responsibility of the ''Design Authority''.<br><br>The full text of applicable '''''RoofStar Guarantee Standards''''' may be read by using the <span style="color:#6495ed">'''blue hyperlinks'''</span>
| |
− | |}
| |
| | | |
− | <div class="panel panel-success">
| |
− | <div class="panel-heading"><big>'''ASM Details'''</big></div>
| |
− | <div class="panel-body">
| |
− | <div class="col-md-6">
| |
− | <div style="text-align:center; vertical-align:center">
| |
− | [[File:ASM 10.2.2 Roof-Headwall Connection (Vented).jpg|class=img-responsive | link=http://rpm.rcabc.org/images/5/5a/ASM_10.2.2_Roof-Headwall_Connection_%28Vented%29.jpg]]
| |
− | </div>
| |
− |
| |
− | ::Click below for a printable version of this page (N/A)
| |
− |
| |
− | <div style="width:150px; text-align: left;">
| |
− | :[[File:Pdf.png|100 px|link=|'''Print Sheet''']]
| |
− | </div>
| |
− | </div><!-- COL-MD-6 -->
| |
− |
| |
− | <div class="col-md-6">
| |
− | === WORK INCLUDED ===
| |
− | ;(1) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMUNDERLAYMENT|'''Underlayment''']]: Applicable for all Architectural Sheet Metal systems. For slopes less than 1:3, the entire roof slope must be covered with a <u>self-adhered</u> underlayment.
| |
− | ;(2) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMSEP-VENT|'''Ventilation material''']]: A ventilation space is required on slopes less than 1:3; entangled mesh (shown) may be used as void fill. The ventilation space facilitates drying as condensation forms on the underside of the metal panels.
| |
− | ;(3) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMCLIP|'''Metal Panel Clip''']]: Installed to metal roof panel manufacturer's printed instructions.
| |
− | ;(4) Bearing plate: Used to support clips and distribute dead and live loads when direct contact with a solid substrate is not possible.
| |
− | ;(5) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMPANEL |'''Architectural metal roof panel''']]
| |
− | ;(6) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMZ |''''Z'-Closure''']]: Set in acceptable sealant and secured with compatible, non-corrosive, flat head fasteners.
| |
− | ;(7) Perforated ventilation metal: Mechanically fastened to wall and 'Z'-closure. The outer edge serves as a hook for the roof-wall metal flashing.
| |
− | ;(8) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMSHEETMETAL |'''Sheet Metal Flashing''']]: Hooked to perforated ventilation metal and fastened to wall with non-corrosive, flat head fasteners 300 mm (12") o/c or preformed foam closures set in acceptable sealant with high domed gasketed cladding type screws at each standing rib.
| |
− | ;(9) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMCOUNTER |'''Metal Counter Flashing''']]: Must extend behind wall system and wall control layers. Stucco stops are not considered to be a counter flashing.
| |
− |
| |
− | <hr>
| |
− |
| |
− | === RELATED WORK BY OTHERS ===
| |
− | ;(A) [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems#ASMDECK|'''Acceptable deck''']]
| |
− | ;(B) '''Wall control layers''': must be positively lapped with roof materials and flashings, to maintain continuity across systems.
| |
− | ;(C) '''Wall cladding''':
| |
− | </div><!-- COL-6-MD -->
| |
− | </div><!-- PANEL BODY -->
| |
− | </div><!-- PANEL -->
| |
− |
| |
− | '''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
| |
− |
| |
− | <hr>
| |
− |
| |
− | [[RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems|<i class="fa fa-chevron-circle-right fa" ></i> RoofStar Guarantee Standards for Architectural Sheet Metal (ASM) Systems]]
| |
− |
| |
− | [[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']]
| |