Difference between revisions of "Building Ventilation"
Difference between revisions of "Building Ventilation"
(→Attic and Roof Space Ventilation) |
(→Attic and Roof Space Ventilation) |
||
Line 49: | Line 49: | ||
Requirements for Residential and Small Buildings (BC Building Code Section 9.19) | Requirements for Residential and Small Buildings (BC Building Code Section 9.19) | ||
− | {| class="wikitable" style=" | + | {| class="wikitable" style="vertical-align:top; margin-left: 20pt; margin-right: auto; border: none;" |
|+ BCBC Ventilation Design Requirements | |+ BCBC Ventilation Design Requirements | ||
|- | |- | ||
− | ! style="width:500px;" | Continuous Ridge Vent and Soffit Ventilation | + | ! style="width:500px;"| Continuous Ridge Vent and Soffit Ventilation |
− | ! style="width:500px;" | Gable End Vents and Soffit Ventilation | + | ! style="width:500px;"| Gable End Vents and Soffit Ventilation |
|- | |- | ||
− | | [[File:ContinuousRidgeandSoffit.jpg]] || [[File:GableEndVentsandSoffit.jpg]] | + | | style="text-align:center;" | [[File:ContinuousRidgeandSoffit.jpg]] || style="text-align:center;" | [[File:GableEndVentsandSoffit.jpg]] |
|- | |- | ||
− | | Where insulation is installed between ceilings and the underside of roof sheathing, space shall be provided between the insulation and roof sheathing, and vents shall be installed to permit the transfer of moisture from the space to the exterior. (See Section 9.19 BC Building Code) Vents shall be in conformance with CAN3-A93 natural ventilators for buildings and shall be designed to prevent the entry of rain, snow and insects. || Ceiling insulation shall not be installed in a manner that will restrict free flow of air though roof vents or through any portion of the attic or roof space. The unobstructed vent shall be not less than 1/300 of the insulated ceiling area. On roofs sloped less than 1:6 (2” in 12”), that are constructed with roof joists, the vent shall not be less than 1/150 of the insulated ceiling area. | + | | style="text-align:left;" | Where insulation is installed between ceilings and the underside of roof sheathing, space shall be provided between the insulation and roof sheathing, and vents shall be installed to permit the transfer of moisture from the space to the exterior. (See Section 9.19 BC Building Code) Vents shall be in conformance with CAN3-A93 natural ventilators for buildings and shall be designed to prevent the entry of rain, snow and insects. || Ceiling insulation shall not be installed in a manner that will restrict free flow of air though roof vents or through any portion of the attic or roof space. The unobstructed vent shall be not less than 1/300 of the insulated ceiling area. On roofs sloped less than 1:6 (2” in 12”), that are constructed with roof joists, the vent shall not be less than 1/150 of the insulated ceiling area. |
|- | |- | ||
|} | |} | ||
− | {| class="wikitable" style=" | + | {| class="wikitable" style="vertical-align:top; margin-left: 20pt; margin-right: auto; border: none;" |
− | |+ | + | |+ Cathedral and Soffit Ventilation |
|- | |- | ||
− | ! style="width:500px;" | Cathedral Ceiling | + | ! style="width:500px;"| Cathedral Ceiling |
− | ! style="width:500px;" | Roof Air Vents and Soffit Ventilation | + | ! style="width:500px;"| Roof Air Vents and Soffit Ventilation |
|- | |- | ||
− | | Spaced Purlins provide air space || | + | | style="text-align:center;" | Spaced Purlins provide air space || |
|- | |- | ||
− | | [[File:RoofAirVentsandSoffit.jpg]] || [[File:RoofAirVentsandSoffit.jpg]] | + | | style="text-align:center;" | [[File:RoofAirVentsandSoffit.jpg]] || style="text-align:center;" | [[File:RoofAirVentsandSoffit.jpg]] |
|- | |- | ||
− | | Where each joist space is not separately vented, roof joist spaces shall be interconnected by installing purlins not less than 38 mm (1 1/2 ”) by 38 mm (1 1/2 ”) on top of the roof joists. Not less than 63 mm (2 1/2 ”) of space shall be provided between the top of the insulation and the underside of the roof sheathing. || Vents may be roof, eave or gable end type or any combination thereof, as long as adequate ventilation is provided. The vents must be distributed uniformly on opposite sides of the building. Not less than 25% of required vent openings shall be located at the top of the attic or roof space, and not less than 25% of the required openings shall be located at the bottom of the space. The lower portion of the mansard or gambrel style roofs does not need to be ventilated. The upper portion requires ventilation as noted above. | + | | style="text-align:left;" | Where each joist space is not separately vented, roof joist spaces shall be interconnected by installing purlins not less than 38 mm (1 1/2 ”) by 38 mm (1 1/2 ”) on top of the roof joists. Not less than 63 mm (2 1/2 ”) of space shall be provided between the top of the insulation and the underside of the roof sheathing. || Vents may be roof, eave or gable end type or any combination thereof, as long as adequate ventilation is provided. The vents must be distributed uniformly on opposite sides of the building. Not less than 25% of required vent openings shall be located at the top of the attic or roof space, and not less than 25% of the required openings shall be located at the bottom of the space. The lower portion of the mansard or gambrel style roofs does not need to be ventilated. The upper portion requires ventilation as noted above. |
|- | |- | ||
|} | |} |
Revision as of 17:08, 18 July 2016
Contents
1 General
This section of the RCABC Roofing Practices Manual provides general information on the benefits, types of vents and BC Building Code Requirements for attic and roof space ventilation. The Reader is urged to consult all relevant codes governing construction design and practices in any given jurisdiction.
1.1 Benefits of Attic Ventilation
1.2 Types of Pitched Roof Attic Vents
1.3 Attic and Roof Space Ventilation
Requirements for Residential and Small Buildings (BC Building Code Section 9.19)