Difference between revisions of "ASM Eave Protection and Underlayment"
Difference between revisions of "ASM Eave Protection and Underlayment"
(→RELATED WORK BY OTHERS) |
(→RELATED WORK BY OTHERS) |
||
Line 23: | Line 23: | ||
;(A) <b>Acceptable Deck</b> | ;(A) <b>Acceptable Deck</b> | ||
− | + | ||
+ | '''NOTE''': Refer to <i>RGC Guarantee Standards</i> for additional requirements.] | ||
+ | |||
<hr> | <hr> | ||
+ | |||
+ | |||
Revision as of 18:48, 19 July 2016
1 WORK INCLUDED
- (1) Underlayment
- Proprietary underlayment installed perpendicular to the slope with 50 mm (2") minimum side laps and 100 mm (4") minimum end laps.
- (2) Ice And Water Protection
- One ply of accepted self-adhered modified bituminous membrane.
- (3) Edge Metal Flashing
- Installed to manufacturer’s printed instructions.
- Note
- This specification is only applicable to slopes 1
- 3 (4" in 12") or greater
- Slip sheet not shown for clarity
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
NOTE: Refer to RGC Guarantee Standards for additional requirements.]