1 WORK INCLUDED

(1) Underlayment and Eave Protection
One ply of self-adhered modified bituminous underlayment material. Lap 50 mm (2") minimum on sides and 100 mm (4") minimum on ends.
(2) Edge Metal Flashing
Installed to manufacturer's printed instructions.
Note: This specification is applicable to slopes 1:6 (2" in 12") and greater.


2 RELATED WORK BY OTHERS

(A) Acceptable Deck


NOTE: Refer to RoofStar Guarantee Standards for additional requirements.