Difference between revisions of "ASM Eave and Rake Edges (Snap-Lock Seams)"
Difference between revisions of "ASM Eave and Rake Edges (Snap-Lock Seams)"
(→RELATED WORK BY OTHERS) |
|||
Line 1: | Line 1: | ||
− | |||
[[File:8.1.4.4.1.jpg]] | [[File:8.1.4.4.1.jpg]] | ||
=== WORK INCLUDED === | === WORK INCLUDED === | ||
+ | ;(1) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMICE|'''Ice and Water Protection''']]: Accepted self-adhered modified bituminous membrane. | ||
+ | ;(2) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMSLIP|'''Slip Sheet''']]: Recommended over asphaltic underlays and / or as required by metal panel manufacturer. | ||
+ | ;(3) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLIP|'''Metal Panel Clip''']]: Installed to metal roof panel manufacturer's printed instructions. | ||
+ | ;(4) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMPANEL |'''Architectural Metal Roof Panel''']] | ||
+ | ;(5) '''Continuous Metal Cleat''' | ||
+ | ;(6) '''Metal Fascia Flashing''' | ||
+ | ;(7) '''Edge Metal Flashing (Continuous)''' | ||
+ | ;(8) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMCLOSURE |'''Pre-formed Closures''']] | ||
+ | ;(9) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMEXFASTEN |'''Exposed Fasteners''']]: High-domed gasketed cladding type screws compatible with metal roof panel. | ||
+ | ;(10) '''Rake Edge Metal Flashing''' | ||
− | + | <hr> | |
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
=== RELATED WORK BY OTHERS === | === RELATED WORK BY OTHERS === | ||
+ | ;(A) [[RoofStar Guarantee Standards for ASM Roof Systems#ASMDECK|'''Acceptable Deck''']] | ||
+ | ;(B) '''Fascia Board''' | ||
− | |||
− | |||
− | |||
− | '''NOTE''': Refer to | + | '''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements. |
Line 41: | Line 30: | ||
− | [[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa | + | [[Section:E. Application: Steep Slope Roofs|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Application'']] |
− | [[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[Architectural Sheet Metal Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''ASM Construction Details'']] |
− | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa | + | [[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']] |
Revision as of 18:52, 9 August 2016
1 WORK INCLUDED
- (1) Ice and Water Protection
- Accepted self-adhered modified bituminous membrane.
- (2) Slip Sheet
- Recommended over asphaltic underlays and / or as required by metal panel manufacturer.
- (3) Metal Panel Clip
- Installed to metal roof panel manufacturer's printed instructions.
- (4) Architectural Metal Roof Panel
- (5) Continuous Metal Cleat
- (6) Metal Fascia Flashing
- (7) Edge Metal Flashing (Continuous)
- (8) Pre-formed Closures
- (9) Exposed Fasteners
- High-domed gasketed cladding type screws compatible with metal roof panel.
- (10) Rake Edge Metal Flashing
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
- (B) Fascia Board
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.