Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"

Jump to: navigation, search

Difference between revisions of "WP Details:F1.7.2 (Wearing Course - Unit Masonry)"

Line 1: Line 1:
<hr>
+
<div class="panel panel-success">
[[File:9.6.2.jpg]]
+
<div class="panel-heading"><big>'''Waterproofing Details for Plazas, Promenades and Terraces'''</big></div>
 
+
<div class="panel-body">
 +
<div class="col-md-6">
 +
<div style="text-align:center; vertical-align:center">
 +
[[File:9.6.2.jpg|class=img-responsive]]
 +
</div>
 +
</div><!-- COL-MD-6 -->
  
 +
<div class="col-md-6">
 
=== WORK INCLUDED ===
 
=== WORK INCLUDED ===
  
Line 23: Line 29:
 
(C) <b>Conductive Tape: </b>Moisture Survey System (tape grid) <b>mandatory</b> and compliant with RGC Guarantee Standards <b>E.</b> For RGC accepted Moisture Survey Tape System s - refer to Section 2.2.  
 
(C) <b>Conductive Tape: </b>Moisture Survey System (tape grid) <b>mandatory</b> and compliant with RGC Guarantee Standards <b>E.</b> For RGC accepted Moisture Survey Tape System s - refer to Section 2.2.  
  
;NOTE: Refer to RGC Guarantee Standards E for additional requirements.
+
</div><!-- COL-6-MD -->
 +
</div><!-- PANEL BODY -->
 +
</div><!-- PANEL -->
 +
 
 +
'''NOTE''': Refer to '''''RoofStar Guarantee Standards''''' for additional requirements.
  
 
<hr>
 
<hr>
Line 29: Line 39:
  
  
[[Section:F. Application: Waterproofing Plazas, Promenades and Terraces|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Waterproofing Application'']]
 
  
[[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Waterproofing Construction Details'']]
+
[[Section:F. Application: Waterproofing Plazas, Promenades and Terraces|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Application'']]
 +
[[Waterproofing Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Waterproofing Construction Details'']]
  
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa-2x" ></i> Back to ''Construction Details'']]
+
[[Section:G. Construction Details|<i class="fa fa-chevron-circle-left fa" ></i> Back to ''Construction Details'']]

Revision as of 21:31, 19 August 2016

Waterproofing Details for Plazas, Promenades and Terraces

9.6.2.jpg

1 WORK INCLUDED

(1)Primary Waterproofing Membrane: Fully adhered to acceptable substrates (concrete slab shown), installed as per RGC Guarantee Standards E and Membrane Manufacturer's installation specifications.

(2)Membrane Primer or Adhesive: Proprietary primer or adhesive, application method and quantities for substrate type as directed by membrane manufacturer's published application specifications.

(3)Protection Board/Mat: Proprietary membrane protection board or mat approved by membrane manufacturer, compatible with waterproofing membrane system, and compliant with RGC Guarantee Standards E.

(4) Drainage Medium: Proprietary (purpose-made) geocomposite drainage boards with synthetic water permeable fabric required to contain sand and gravel beds for unit masonry (pavers, bricks, and stone).


2 WORK BY OTHERS

(A) Acceptable Deck: Concrete slab depicted.

(B) Unit Masonry Wearing Coarse: Concrete brick, pavers, stone on sand and gravel or moror beds designed to support predicted live loads.

(C) Conductive Tape: Moisture Survey System (tape grid) mandatory and compliant with RGC Guarantee Standards E. For RGC accepted Moisture Survey Tape System s - refer to Section 2.2.

NOTE: Refer to RoofStar Guarantee Standards for additional requirements.




Back to Waterproofing Application Back to Waterproofing Construction Details