ASM 10.4.4 Ridge (Snap Seam, Notched)
ASM 10.4.4 Ridge (Snap Seam, Notched)
Revision as of 16:27, 26 April 2019 by James Klassen (talk | contribs) (James Klassen moved page ASM Details:E1.7.12 (Notched Ridge / Hip Cap Flashing) to ASM 10.4.4 Ridge (Snap Seam, Notched))
RoofStar Guarantee Standards are blue-linked |
ASM Details
1 WORK INCLUDED
- (1) Underlayment
- The type of underlay required is determined by roof slope.
- (2) Insulation Overlay Protection
- Recommended.
- (3) Architectural Metal Roof Panel
- Turn up (bread panned) at termination.
- (4) 'Z'-Bar
- Installed to meet adequate attachment for UL I-90 wind uplift requirements.
- (5) Insulation
- Installed between ‘Z’ bars or wood battens on 600 mm (24") centres.
- (6) Pre-formed Foam Closures
- Set in accepted caulking.
- (7) Exposed Fasteners
- High domed, gasketed cladding type screws compatible with metal roof panel.
- (8) Metal Cap Flashing
- Joints overlapped 100 mm (4") minimum, sealed with two rows of accepted caulking. Exposed edges must be turned under 12.7 mm (1/2").
- (9) Drag-load Fasteners
- Compatible non-corrosive fasteners.
2 RELATED WORK BY OTHERS
- (A) Acceptable Deck
NOTE: Refer to RoofStar Guarantee Standards for additional requirements.
RoofStar Guarantee Standards for ASM Roof Assemblies