SBS 2-Part Retrofit Flashing (Cable Penetration)

Jump to: navigation, search

SBS 2-Part Retrofit Flashing (Cable Penetration)

Revision as of 20:18, 19 July 2016 by James Klassen (talk | contribs) (RELATED WORK BY OTHERS)

D1.7.6.jpg


1 WORK INCLUDED

(1) Gypsum Overlay Board
Required when insulation is too thin to span flutes of steel decking or as thermal barrier when specified by the design authority. (See RGC Guarantee Standard A2.5).
(2) Vapour Retarder
If required by design authority.
(3) Insulation
Mechanically fastened where possible. (See Section 2.2 for accepted materials and RGC Guarantee Standard A4.4).
(4) Insulation Overlay
As required. See RGC Guarantee Standard C4.1
(5) Base Sheet
Adhered to overlay board using asphalt, cold adhesive, self-adhered, mechanical attachment or torch applied according to manufacturer’s specification and to RGC Guarantee Standards. Torching directly to wood surfaces is not permitted.
(6) Mastic
Compatible with membrane
(7) Base Sheet Flashing
Adhered according to manufacturer’s specifications, using cold adhesive, self-adhered or torch applied. Must be carried up flashing and terminate under hood flange. Torching directly to wood surfaces is not permitted. (See RGC Guarantee Standards Section 2.1.1, A5.6, and Section 2.1.3, C8.5).
(8) Cap Sheet
Applied according to manufacturer’s printed instructions and to RGC Guarantee Standards.
(9) Cap Sheet Flashing
Applied according to manufacturer’s printed instructions and to RGC Guarantee Standards. Must be carried up flashing and terminate under hood flange.


2 RELATED WORK BY OTHERS

(A) Acceptable Deck
(B) Wood Blocking
(C) Two Piece Flashing
Assembled around protrusion, laid in bed of compatible mastic on top of base sheet. Mechanically fasten two componentstogether and fasten flange to wood blocking or deck.


NOTE: Refer to RGC Guarantee Standards for additional requirements.





Back to SBS Application

Back to SBS Construction Details

Back to Construction Details